Change history for item: TeploVest AGD-30-S-M 31.5 kW double-circuit

  1. Donny Darko 09 July 2023 09:53:00
    1. Create: Description #3559306
      Value: Type of heating boiler: gas, max. thermal power: 31.50 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, combustion chamber type: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3559307
      Value: Gas, convection
    3. Create: Burner #3559308
      Value: Gas
    4. Create: Number of circuits #3559309
      Value: Double-circuit
    5. Create: Thermal power #3559310
      Value: 13.90 - 31.50 kW
    6. Create: The combustion chamber #3559311
      Value: Closed
    7. Create: Efficiency #3559312
      Value: 90 %
    8. Create: Control #3559313
      Value: Electronic
    9. Create: Installation #3559314
      Value: Wall-mounted
    10. Create: Mains voltage #3559315
      Value: Single-phase
    11. Create: Peculiarities #3559316
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3559317
      Value: 8 l
    13. Create: Equipment #3559318
      Value: Display
    14. Create: Fuel #3559319
      Value: Natural gas
    15. Create: Natural gas consumption #3559320
      Value: 3.4 cu. m/hour
    16. Create: Nominal pressure of natural gas #3559321
      Value: 19.60 mbar
    17. Create: Heat carrier temperature #3559322
      Value: 30 - 80 °С
    18. Create: Temperature in the DHW circuit #3559323
      Value: 30 - 60 °С
    19. Create: Hot water capacity at t 25°C #3559324
      Value: 17 l/min
    20. Create: Hot water capacity at t 35°C #3559325
      Value: 12 l/min
    21. Create: Max. water pressure in the DHW circuit #3559326
      Value: 6 bar
    22. Create: Max. water pressure in the heating circuit #3559327
      Value: 3 bar
    23. Create: Gas connection #3559328
      Value: 3/4"
    24. Create: Heating circuit connection #3559329
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3559330
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3559331
      Value: 60/100 mm
    27. Create: Dimensions WxHxD #3559332
      Value: 440x700x310 mm
    28. Create: Weight #3559333
      Value: 44 kg
    29. Create: Image #6351082
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id2124266876291212191/orig
    30. Create: Preview image #6351083
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id2124266876291212191/orig
  2. Donny Darko 30 April 2023 09:03:56
    Name: TeploVest AGD-30-S-M 31.5 kW double-circuit; Catalog: Heating boilers