Change history for item: TeploVest AGD-24-B-M 24.15 kW double-circuit

  1. Donny Darko 09 July 2023 09:52:47
    1. Create: Description #3559222
      Value: Type of heating boiler: gas, max. thermal power: 24.15 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: open, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3559223
      Value: Gas, convection
    3. Create: Burner #3559224
      Value: Gas
    4. Create: Number of circuits #3559225
      Value: Double-circuit
    5. Create: Thermal power #3559226
      Value: 10 - 24.15 kW
    6. Create: The combustion chamber #3559227
      Value: Open
    7. Create: Efficiency #3559228
      Value: 90 %
    8. Create: Control #3559229
      Value: Electronic
    9. Create: Installation #3559230
      Value: Wall-mounted
    10. Create: Mains voltage #3559231
      Value: Single-phase
    11. Create: Peculiarities #3559232
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3559233
      Value: 6 l
    13. Create: Equipment #3559234
      Value: Display
    14. Create: Fuel #3559235
      Value: Natural gas
    15. Create: Natural gas consumption #3559236
      Value: 2.9 cu. m/hour
    16. Create: Nominal pressure of natural gas #3559237
      Value: 19.60 mbar
    17. Create: Heat carrier temperature #3559238
      Value: 30 - 80 °С
    18. Create: Temperature in the DHW circuit #3559239
      Value: 30 - 60 °С
    19. Create: Hot water capacity at t 25°C #3559240
      Value: 13 l/min
    20. Create: Hot water capacity at t 35°C #3559241
      Value: 9 l/min
    21. Create: Max. water pressure in the DHW circuit #3559242
      Value: 6 bar
    22. Create: Max. water pressure in the heating circuit #3559243
      Value: 3 bar
    23. Create: Gas connection #3559244
      Value: 3/4"
    24. Create: Heating circuit connection #3559245
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3559246
      Value: 1/2"
    26. Create: Chimney diameter #3559247
      Value: 128 mm
    27. Create: Dimensions WxHxD #3559248
      Value: 420x700x310 mm
    28. Create: Weight #3559249
      Value: 34 kg
    29. Create: Image #6351076
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id2124266876291212191/orig
    30. Create: Preview image #6351077
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id2124266876291212191/orig
  2. Donny Darko 30 April 2023 09:03:55
    Name: TeploVest AGD-24-B-M 24.15 kW double-circuit; Catalog: Heating boilers