Change history for item: Gas KNG-24 24 kW double-circuit

  1. Donny Darko 09 July 2023 09:15:34
    1. Create: Description #3552685
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3552686
      Value: Gas, convection
    3. Create: Burner #3552687
      Value: Gas
    4. Create: Number of circuits #3552688
      Value: Double-circuit
    5. Create: Thermal power #3552689
      Value: 4.60 - 24 kW
    6. Create: The combustion chamber #3552690
      Value: Closed
    7. Create: Heated area #3552691
      Value: 220 sq.m
    8. Create: Efficiency #3552692
      Value: 90.1 %
    9. Create: Control #3552693
      Value: Electronic
    10. Create: Installation #3552694
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3552695
      Value: Copper
    12. Create: Secondary heat exchanger material #3552696
      Value: Stainless steel
    13. Create: Mains voltage #3552697
      Value: Single-phase
    14. Create: Peculiarities #3552698
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: Expansion tank volume #3552699
      Value: 6 l
    16. Create: Equipment #3552700
      Value: Display
    17. Create: Fuel #3552701
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3552702
      Value: 2.6 cu. m/hour
    19. Create: LPG consumption #3552703
      Value: 2.1 kg/hour
    20. Create: Nominal pressure of natural gas #3552704
      Value: 13 mbar
    21. Create: Permissible LPG pressure #3552705
      Value: 30 mbar
    22. Create: Heat carrier temperature #3552706
      Value: 30 - 80 °С
    23. Create: Temperature in the DHW circuit #3552707
      Value: 25 - 60 °C
    24. Create: Hot water capacity at t 25°C #3552708
      Value: 13.6 l/min
    25. Create: Max. water pressure in the DHW circuit #3552709
      Value: 7 bar
    26. Create: Max. water pressure in the heating circuit #3552710
      Value: 3 bar
    27. Create: Gas connection #3552711
      Value: 3/4"
    28. Create: Heating circuit connection #3552712
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3552713
      Value: 1/2"
    30. Create: Dimensions WxHxD #3552714
      Value: 460x730x260mm
    31. Create: Weight #3552715
      Value: 36.5 kg
    32. Create: Image #6350048
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id7396515456553119820/orig
    33. Create: Preview image #6350049
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id7396515456553119820/orig
  2. Donny Darko 30 April 2023 09:02:12
    Name: Gas KNG-24 24 kW double-circuit; Catalog: Heating boilers