Change history for item: Gas KSG-16 E 16 kW single-circuit

  1. Donny Darko 09 July 2023 09:11:22
    1. Create: Description #3551657
      Value: Type of heating boiler: gas, max. thermal power: 16 kW, number of circuits: single-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: non-volatile
    2. Create: Type of heating boiler #3551658
      Value: Gas, convection
    3. Create: Burner #3551659
      Value: Gas
    4. Create: Number of circuits #3551660
      Value: Single-loop
    5. Create: Max. thermal power #3551661
      Value: 16 kW
    6. Create: Max. thermal load #3551662
      Value: 16 kW
    7. Create: Non-volatile #3551663
      Value: Yes
    8. Create: The combustion chamber #3551664
      Value: Open
    9. Create: Heated area #3551665
      Value: 160 sq.m
    10. Create: Efficiency #3551666
      Value: 92 %
    11. Create: Control #3551667
      Value: Mechanical
    12. Create: Installation #3551668
      Value: Floor
    13. Create: Primary heat exchanger material #3551669
      Value: Steel
    14. Create: Secondary heat exchanger material #3551670
      Value: Steel
    15. Create: Mains voltage #3551671
      Value: Non-volatile
    16. Create: Peculiarities #3551672
      Value: Thermometer
    17. Create: The volume of the built-in boiler #3551673
      Value: 22.6 l
    18. Create: Equipment #3551674
      Value: Gas automation EuroSit, thermometer on the front panel
    19. Create: Fuel #3551675
      Value: Natural gas, liquefied gas
    20. Create: Natural gas consumption #3551676
      Value: 1.1 cu. m/hour
    21. Create: LPG consumption #3551677
      Value: 14.1 kg/hour
    22. Create: Nominal pressure of natural gas #3551678
      Value: 13 mbar
    23. Create: Heat carrier temperature #3551679
      Value: 50 - 90 °C
    24. Create: Temperature in the DHW circuit #3551680
      Value: 35 - 75 °С
    25. Create: Max. water pressure in the DHW circuit #3551681
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3551682
      Value: 2 bar
    27. Create: Gas connection #3551683
      Value: 1/2"
    28. Create: Heating circuit connection #3551684
      Value: 1¼
    29. Create: Branch pipe for connecting the DHW circuit #3551685
      Value: No
    30. Create: Chimney diameter #3551686
      Value: 120 mm
    31. Create: Dimensions WxHxD #3551687
      Value: 300x710x470mm
    32. Create: Weight #3551688
      Value: 45 kg
    33. Create: Additional Information #3551689
      Value: Gas control unit 630 EUROSIT
    34. Create: Image #6349933
      URL: https://avatars.mds.yandex.net/get-mpic/5221948/img_id5898100594286032545.jpeg/orig
    35. Create: Image #6349934
      URL: https://avatars.mds.yandex.net/get-mpic/5222168/img_id3017518563220661406.png/orig
    36. Create: Image #6349935
      URL: https://avatars.mds.yandex.net/get-mpic/5376414/img_id3445606100260737432.png/orig
    37. Create: Image #6349936
      URL: https://avatars.mds.yandex.net/get-mpic/7979706/img_id6562107788964129666.png/orig
    38. Create: Image #6349937
      URL: https://avatars.mds.yandex.net/get-mpic/7980098/img_id7460893345548470069.png/orig
    39. Create: Preview image #6349938
      URL: https://avatars.mds.yandex.net/get-mpic/5221948/img_id5898100594286032545.jpeg/orig
  2. Donny Darko 30 April 2023 09:02:00
    Name: Gas KSG-16 E 16 kW single-circuit; Catalog: Heating boilers