Change history for item: KS-GV-16 Sit 16 kW double-circuit

  1. Donny Darko 09 July 2023 08:47:44
    1. Create: Description #3547172
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3547173
      Value: Gas, convection
    3. Create: Burner #3547174
      Value: Gas
    4. Create: Number of circuits #3547175
      Value: Double-circuit
    5. Create: Max. thermal power #3547176
      Value: 16 kW
    6. Create: Non-volatile #3547177
      Value: Yes
    7. Create: The combustion chamber #3547178
      Value: Open
    8. Create: Heated area #3547179
      Value: 160 sq.m
    9. Create: Efficiency #3547180
      Value: 90 %
    10. Create: Control #3547181
      Value: Mechanical
    11. Create: Installation #3547182
      Value: Floor
    12. Create: Primary heat exchanger material #3547183
      Value: Steel
    13. Create: Secondary heat exchanger material #3547184
      Value: Copper
    14. Create: Peculiarities #3547185
      Value: Thermometer
    15. Create: Fuel #3547186
      Value: Natural gas
    16. Create: Natural gas consumption #3547187
      Value: 2.06 cu. m/hour
    17. Create: Nominal pressure of natural gas #3547188
      Value: 6.35 - 17.64 mbar
    18. Create: Heat carrier temperature #3547189
      Value: 40 - 90 °С
    19. Create: Hot water capacity at t 25°C #3547190
      Value: 7.5 l/min
    20. Create: Hot water capacity at t 35°C #3547191
      Value: 4.5 l/min
    21. Create: Max. water pressure in the DHW circuit #3547192
      Value: 6 bar
    22. Create: Max. water pressure in the heating circuit #3547193
      Value: 3 bar
    23. Create: Gas connection #3547194
      Value: 1/2"
    24. Create: Heating circuit connection #3547195
      Value: 2"
    25. Create: Branch pipe for connecting the DHW circuit #3547196
      Value: 1/2"
    26. Create: Chimney diameter #3547197
      Value: 133 mm
    27. Create: Dimensions WxHxD #3547198
      Value: 380x835x500 mm
    28. Create: Weight #3547199
      Value: 50 kg
    29. Create: Additional Information #3547200
      Value: EUROSIT security automation
    30. Create: Image #6349232
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id2904647055321949566/orig
    31. Create: Image #6349233
      URL: https://avatars.mds.yandex.net/get-mpic/397397/img_id7468637593801576283/orig
    32. Create: Preview image #6349234
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id2904647055321949566/orig
  2. Donny Darko 30 April 2023 09:01:02
    Name: KS-GV-16 Sit 16 kW double-circuit; Catalog: Heating boilers