Change history for item: ROC Mini B11A2 11 kW dual circuit

  1. Donny Darko 09 July 2023 08:44:52
    1. Create: Description #3546617
      Value: Type of heating boiler: gas, max. thermal power: 11 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3546618
      Value: Gas, convection
    3. Create: Burner #3546619
      Value: Gas
    4. Create: Number of circuits #3546620
      Value: Double-circuit
    5. Create: Thermal power #3546621
      Value: 3.20 - 11 kW
    6. Create: Thermal load #3546622
      Value: 3.70 - 12.20 kW
    7. Create: The combustion chamber #3546623
      Value: Open
    8. Create: Efficiency #3546624
      Value: 90 %
    9. Create: Control #3546625
      Value: Electronic
    10. Create: Installation #3546626
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3546627
      Value: Copper
    12. Create: Mains voltage #3546628
      Value: Single-phase
    13. Create: Peculiarities #3546629
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3546630
      Value: 5 l
    15. Create: Equipment #3546631
      Value: Display
    16. Create: Fuel #3546632
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3546633
      Value: 1.21 cu. m/hour
    18. Create: Nominal pressure of natural gas #3546634
      Value: 13 - 25 mbar
    19. Create: Heat carrier temperature #3546635
      Value: 30 - 85 °С
    20. Create: Temperature in the DHW circuit #3546636
      Value: 30 - 60 °С
    21. Create: Hot water capacity at t 25°C #3546637
      Value: 7.1 l/min
    22. Create: Max. water pressure in the DHW circuit #3546638
      Value: 8 bar
    23. Create: Max. water pressure in the heating circuit #3546639
      Value: 3 bar
    24. Create: Gas connection #3546640
      Value: 3/4"
    25. Create: Heating circuit connection #3546641
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3546642
      Value: 1/2"
    27. Create: Chimney diameter #3546643
      Value: 130 mm
    28. Create: Dimensions WxHxD #3546644
      Value: 400x660x250mm
    29. Create: Weight #3546645
      Value: 26 kg
    30. Create: Image #6349155
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id1020998472147491687/orig
    31. Create: Preview image #6349156
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id1020998472147491687/orig
  2. Donny Darko 30 April 2023 09:00:55
    Name: ROC Mini B11A2 11 kW dual circuit; Catalog: Heating boilers