Change history for item: ROC Platinum B40F2 37.5 kW double circuit

  1. Donny Darko 09 July 2023 08:44:32
    1. Create: Description #3546476
      Value: Type of heating boiler: gas, max. thermal power: 37.50 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, combustion chamber type: closed, power type: single-phase, control: electric
    2. Create: Type of heating boiler #3546477
      Value: Gas, condensing
    3. Create: Burner #3546478
      Value: Gas
    4. Create: Number of circuits #3546479
      Value: Double-circuit
    5. Create: Thermal power #3546480
      Value: 6.20 - 37.50 kW
    6. Create: Thermal load #3546481
      Value: 6.60 - 40.10 kW
    7. Create: The combustion chamber #3546482
      Value: Closed
    8. Create: Efficiency #3546483
      Value: 104 %
    9. Create: Control #3546484
      Value: Electronic
    10. Create: Installation #3546485
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3546486
      Value: Stainless steel
    12. Create: Mains voltage #3546487
      Value: Single-phase
    13. Create: Peculiarities #3546488
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3546489
      Value: 65 l
    15. Create: Equipment #3546490
      Value: Display
    16. Create: Fuel #3546491
      Value: Natural gas
    17. Create: Natural gas consumption #3546492
      Value: 3.97 cu. m/hour
    18. Create: Nominal pressure of natural gas #3546493
      Value: 20 mbar
    19. Create: Heat carrier temperature #3546494
      Value: 30 - 85 °С
    20. Create: Temperature in the DHW circuit #3546495
      Value: 30 - 60 °С
    21. Create: Hot water capacity at t 25°C #3546496
      Value: 23.4 l/min
    22. Create: Max. water pressure in the DHW circuit #3546497
      Value: 8 bar
    23. Create: Max. water pressure in the heating circuit #3546498
      Value: 3 bar
    24. Create: Gas connection #3546499
      Value: 3/4"
    25. Create: Heating circuit connection #3546500
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3546501
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3546502
      Value: 60/100 mm
    28. Create: Dimensions WxHxD #3546503
      Value: 460x760x280mm
    29. Create: Weight #3546504
      Value: 41 kg
    30. Create: Image #6349145
      URL: https://avatars.mds.yandex.net/get-mpic/4393885/img_id8603554249706501391.jpeg/orig
    31. Create: Preview image #6349146
      URL: https://avatars.mds.yandex.net/get-mpic/4393885/img_id8603554249706501391.jpeg/orig
  2. Donny Darko 30 April 2023 09:00:53
    Name: ROC Platinum B40F2 37.5 kW double circuit; Catalog: Heating boilers