Change history for item: ROC Optima B18A1 18 kW dual circuit

  1. Donny Darko 09 July 2023 08:41:00
    1. Create: Description #3545639
      Value: Type of heating boiler: gas, max. thermal power: 18 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3545640
      Value: Gas, convection
    3. Create: Burner #3545641
      Value: Gas
    4. Create: Number of circuits #3545642
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3545643
      Value: 6 - 18 kW
    6. Create: Thermal load #3545644
      Value: 6.70 - 20 kW
    7. Create: The combustion chamber #3545645
      Value: Open
    8. Create: Efficiency #3545646
      Value: 90 %
    9. Create: Control #3545647
      Value: Electronic
    10. Create: Installation #3545648
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3545649
      Value: Copper
    12. Create: Mains voltage #3545650
      Value: Single-phase
    13. Create: Peculiarities #3545651
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3545652
      Value: 6 l
    15. Create: Equipment #3545653
      Value: Display
    16. Create: Fuel #3545654
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3545655
      Value: 2.12 cu. m/hour
    18. Create: Nominal pressure of natural gas #3545656
      Value: 13 - 25 mbar
    19. Create: Heat carrier temperature #3545657
      Value: 30 - 85 °С
    20. Create: Temperature in the DHW circuit #3545658
      Value: 30 - 60 °С
    21. Create: Hot water capacity at t 25°C #3545659
      Value: 9.5 l/min
    22. Create: Max. water pressure in the DHW circuit #3545660
      Value: 8 bar
    23. Create: Max. water pressure in the heating circuit #3545661
      Value: 3 bar
    24. Create: Gas connection #3545662
      Value: 3/4"
    25. Create: Heating circuit connection #3545663
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3545664
      Value: 1/2"
    27. Create: Chimney diameter #3545665
      Value: 130 mm
    28. Create: Dimensions WxHxD #3545666
      Value: 460x760x230mm
    29. Create: Weight #3545667
      Value: 31 kg
    30. Create: Image #6349085
      URL: https://avatars.mds.yandex.net/get-mpic/4252138/img_id3006167170721369121.jpeg/orig
    31. Create: Preview image #6349086
      URL: https://avatars.mds.yandex.net/get-mpic/4252138/img_id3006167170721369121.jpeg/orig
  2. Donny Darko 30 April 2023 09:00:44
    Name: ROC Optima B18A1 18 kW dual circuit; Catalog: Heating boilers