Change history for item: Koreastar Bravo 20

  1. Donny Darko 09 July 2023 08:29:54
    1. Create: Description #3542934
      Value: Type of heating boiler: gas, max. thermal power: 20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3542935
      Value: Gas, convection
    3. Create: Burner #3542936
      Value: Gas
    4. Create: Number of circuits #3542937
      Value: Double-circuit
    5. Create: Thermal power #3542938
      Value: 8.15 - 20 kW
    6. Create: The combustion chamber #3542939
      Value: Closed
    7. Create: Heated area #3542940
      Value: 200 sq.m
    8. Create: Efficiency #3542941
      Value: 91.2 %
    9. Create: Control #3542942
      Value: Electronic
    10. Create: Installation #3542943
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3542944
      Value: Copper
    12. Create: Secondary heat exchanger material #3542945
      Value: Steel
    13. Create: Mains voltage #3542946
      Value: Single-phase
    14. Create: Peculiarities #3542947
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    15. Create: Expansion tank volume #3542948
      Value: 6 l
    16. Create: Equipment #3542949
      Value: Display
    17. Create: Fuel #3542950
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3542951
      Value: 2.14 cu. m/hour
    19. Create: LPG consumption #3542952
      Value: 1.65 kg/hour
    20. Create: Nominal pressure of natural gas #3542953
      Value: 10 - 25 mbar
    21. Create: Permissible LPG pressure #3542954
      Value: 37 mbar
    22. Create: Heat carrier temperature #3542955
      Value: 30 - 85 °С
    23. Create: Temperature in the DHW circuit #3542956
      Value: 35 - 55 °С
    24. Create: Hot water capacity at t 25°C #3542957
      Value: 13.6 l/min
    25. Create: Hot water capacity at t 30°C #3542958
      Value: 11.3 l/min
    26. Create: Max. water pressure in the DHW circuit #3542959
      Value: 8 bar
    27. Create: Max. water pressure in the heating circuit #3542960
      Value: 3 bar
    28. Create: Gas connection #3542961
      Value: 1/2"
    29. Create: Heating circuit connection #3542962
      Value: 3/4"
    30. Create: Branch pipe for connecting the DHW circuit #3542963
      Value: 1/2"
    31. Create: Coaxial chimney diameter #3542964
      Value: 60/100 mm
    32. Create: Connection of a separate chimney diameter 80 mm #3542965
      Value: Yes
    33. Create: Dimensions WxHxD #3542966
      Value: 440x742x235 mm
    34. Create: Weight #3542967
      Value: 35 kg
    35. Create: Image #6348835
      URL: https://avatars.mds.yandex.net/get-mpic/175985/img_id4558866891120069631/orig
    36. Create: Preview image #6348836
      URL: https://avatars.mds.yandex.net/get-mpic/175985/img_id4558866891120069631/orig
  2. Donny Darko 30 April 2023 09:00:20
    Name: Koreastar Bravo 20; Catalog: Heating boilers