    1. Create: Description #3541799
      Value: Type of heating boiler: gas, max. thermal power: 30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3541800
      Value: Gas, convection
    3. Create: Burner #3541801
      Value: Gas
    4. Create: Number of circuits #3541802
      Value: Double-circuit
    5. Create: Thermal power #3541803
      Value: 12.10 - 30 kW
    6. Create: The combustion chamber #3541804
      Value: Closed
    7. Create: Heated area #3541805
      Value: 300 sq.m
    8. Create: Efficiency #3541806
      Value: 93.1 %
    9. Create: Control #3541807
      Value: Electronic
    10. Create: Installation #3541808
      Value: Wall-mounted
    11. Create: Mains voltage #3541809
      Value: Single-phase
    12. Create: Peculiarities #3541810
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    13. Create: Expansion tank volume #3541811
      Value: 8 l
    14. Create: Equipment #3541812
      Value: Display
    15. Create: Fuel #3541813
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3541814
      Value: 3.34 cu. m/hour
    17. Create: LPG consumption #3541815
      Value: 2.56 kg/h
    18. Create: Nominal pressure of natural gas #3541816
      Value: 10 - 25 mbar
    19. Create: Permissible LPG pressure #3541817
      Value: 28 mbar
    20. Create: Heat carrier temperature #3541818
      Value: 30 - 90 °С
    21. Create: Temperature in the DHW circuit #3541819
      Value: 35 - 55 °С
    22. Create: Hot water capacity at t 25°C #3541820
      Value: 17.2 l/min
    23. Create: Hot water capacity at t 30°C #3541821
      Value: 14.3 l/min
    24. Create: Max. water pressure in the DHW circuit #3541822
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3541823
      Value: 3 bar
    26. Create: Gas connection #3541824
      Value: 1/2"
    27. Create: Heating circuit connection #3541825
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3541826
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3541827
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3541828
      Value: Yes
    31. Create: Dimensions WxHxD #3541829
      Value: 440x742x334 mm
    32. Create: Weight #3541830
      Value: 37.5 kg
    33. Create: Image #6348737