Change history for item: Koreastar Premium 10E

  1. Donny Darko 09 July 2023 08:24:29
    1. Create: Description #3541668
      Value: Type of heating boiler: gas, max. thermal power: 11 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3541669
      Value: Gas, convection
    3. Create: Burner #3541670
      Value: Gas
    4. Create: Number of circuits #3541671
      Value: Double-circuit
    5. Create: Thermal power #3541672
      Value: 8.15 - 11 kW
    6. Create: The combustion chamber #3541673
      Value: Closed
    7. Create: Heated area #3541674
      Value: 110 sq.m
    8. Create: Efficiency #3541675
      Value: 93.1 %
    9. Create: Control #3541676
      Value: Electronic
    10. Create: Installation #3541677
      Value: Wall-mounted
    11. Create: Mains voltage #3541678
      Value: Single-phase
    12. Create: Peculiarities #3541679
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    13. Create: Expansion tank volume #3541680
      Value: 6 l
    14. Create: Equipment #3541681
      Value: Display
    15. Create: Fuel #3541682
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3541683
      Value: 1.32 cu. m/hour
    17. Create: LPG consumption #3541684
      Value: 1.06 kg/hour
    18. Create: Nominal pressure of natural gas #3541685
      Value: 10 - 25 mbar
    19. Create: Permissible LPG pressure #3541686
      Value: 28 mbar
    20. Create: Heat carrier temperature #3541687
      Value: 30 - 90 °С
    21. Create: Temperature in the DHW circuit #3541688
      Value: 35 - 55 °С
    22. Create: Hot water capacity at t 25°C #3541689
      Value: 13.6 l/min
    23. Create: Hot water capacity at t 30°C #3541690
      Value: 11.3 l/min
    24. Create: Max. water pressure in the DHW circuit #3541691
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3541692
      Value: 3 bar
    26. Create: Gas connection #3541693
      Value: 1/2"
    27. Create: Heating circuit connection #3541694
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3541695
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3541696
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3541697
      Value: Yes
    31. Create: Dimensions WxHxD #3541698
      Value: 440x742x235 mm
    32. Create: Weight #3541699
      Value: 35 kg
    33. Create: Image #6348729
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id7971571044339304778/orig
    34. Create: Preview image #6348730
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id7971571044339304778/orig
  2. Donny Darko 30 April 2023 09:00:11
    Name: Koreastar Premium 10E; Catalog: Heating boilers