Change history for item: Bauertherm PREMIER 20W 20 kW double circuit

  1. Donny Darko 09 July 2023 08:23:58
    1. Create: Description #3541562
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3541563
      Value: Gas, convection
    3. Create: Burner #3541564
      Value: Gas
    4. Create: Number of circuits #3541565
      Value: Double-circuit
    5. Create: Max. thermal power #3541566
      Value: 20 kW
    6. Create: Max. thermal load #3541567
      Value: 23 kW
    7. Create: Non-volatile #3541568
      Value: Yes
    8. Create: The combustion chamber #3541569
      Value: Open
    9. Create: Heated area #3541570
      Value: 200 sq.m
    10. Create: Efficiency #3541571
      Value: 87 %
    11. Create: Control #3541572
      Value: Mechanical
    12. Create: Installation #3541573
      Value: Floor
    13. Create: Primary heat exchanger material #3541574
      Value: Steel
    14. Create: Peculiarities #3541575
      Value: Thermometer
    15. Create: Fuel #3541576
      Value: Natural gas
    16. Create: Nominal pressure of natural gas #3541577
      Value: 13 mbar
    17. Create: Max. coolant temperature #3541578
      Value: 90 °С
    18. Create: Hot water capacity at t 35°C #3541579
      Value: 6 l/min
    19. Create: Max. water pressure in the heating circuit #3541580
      Value: 2 bar
    20. Create: Gas connection #3541581
      Value: 1/2"
    21. Create: Heating circuit connection #3541582
      Value: 1¼
    22. Create: Branch pipe for connecting the DHW circuit #3541583
      Value: 1/2"
    23. Create: Chimney diameter #3541584
      Value: 130 mm
    24. Create: Dimensions WxHxD #3541585
      Value: 450x920x570 mm
    25. Create: Weight #3541586
      Value: 69 kg
    26. Create: Additional Information #3541587
      Value: EUROSIT automation unit
    27. Create: Image #6348721
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id2928463058688578732/orig
    28. Create: Preview image #6348722
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id2928463058688578732/orig
  2. Donny Darko 30 April 2023 09:00:09
    Name: Bauertherm PREMIER 20W 20 kW double circuit; Catalog: Heating boilers