Change history for item: Gas floor boiler OLYMPIA OLB-170G-R, 19.8 kW, 160-190 sq.m.

  1. Donny Darko 09 July 2023 08:12:51
    1. Create: Width #34227
      Value: 50
    2. Create: Height #34228
      Value: 94
    3. Create: Description #3539993
      Value: Type of heating boiler: gas, max. heating power: 19.70 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    4. Create: Type of heating boiler #3539994
      Value: Gas
    5. Create: Number of circuits #3539995
      Value: Double-circuit
    6. Create: The principle of operation of a gas boiler #3539996
      Value: Convection
    7. Create: Combustion chamber type #3539997
      Value: Closed
    8. Create: Primary heat exchanger material #3539998
      Value: Steel
    9. Create: Accommodation #3539999
      Value: Floor
    10. Create: Power type #3540000
      Value: Single-phase
    11. Create: Control #3540001
      Value: Electronic
    12. Create: Equipment #3540002
      Value: Room thermostat
    13. Create: Functions #3540003
      Value: Auto diagnostics
    14. Create: Max. thermal power #3540004
      Value: 19.7 kW
    15. Create: Efficiency #3540005
      Value: 91 %
    16. Create: Heated area #3540006
      Value: 190 m²
    17. Create: Maximum water pressure in the heating circuit #3540007
      Value: 3 bar
    18. Create: Maximum coolant temperature #3540008
      Value: 85°C
    19. Create: Gas connection #3540009
      Value: 1/2"
    20. Create: Heating circuit connection #3540010
      Value: 1"
    21. Create: Branch pipe for connecting the DHW circuit #3540011
      Value: 1/2"
    22. Create: Chimney diameter #3540012
      Value: 75 mm
    23. Create: Coaxial chimney diameter #3540013
      Value: 80/110 mm
    24. Create: Separate chimney 80x80 mm #3540014
      Value: There is
    25. Create: Burner #3540015
      Value: Gas
    26. Create: Maximum temperature in the DHW circuit #3540016
      Value: 85°C
    27. Create: Maximum water pressure in the DHW circuit #3540017
      Value: 5 bar
    28. Create: Recommended fuel #3540018
      Value: Natural gas
    29. Create: Fuel #3540019
      Value: Natural gas, liquefied gas
    30. Create: Hot water capacity at t 40°C #3540020
      Value: 7.08 l/min
    31. Create: Depth #3540021
      Value: 60 mm
    32. Create: Weight #3540022
      Value: 71 kg
    33. Create: Additional Information #3540023
      Value: Connection of heating pipes is possible both on the right and on the left. Connection of domestic hot water pipes at the back.
    34. Create: Image #6348527
      URL: https://avatars.mds.yandex.net/get-mpic/4559636/img_id3550313538859151448.jpeg/orig
    35. Create: Preview image #6348528
      URL: https://avatars.mds.yandex.net/get-mpic/4559636/img_id3550313538859151448.jpeg/orig
  2. Donny Darko 30 April 2023 08:59:39
    Name: Gas floor boiler OLYMPIA OLB-170G-R, 19.8 kW, 160-190 sq.m.; Catalog: Heating boilers