Change history for item: Combined boiler Olympia OLB-350 G-R 35 kW double-circuit

  1. Donny Darko 09 July 2023 08:12:13
    1. Create: Description #3539833
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3539834
      Value: Gas, convection
    3. Create: Burner #3539835
      Value: Gas
    4. Create: Number of circuits #3539836
      Value: Double-circuit
    5. Create: Max. thermal power #3539837
      Value: 35 kW
    6. Create: Max. thermal load #3539838
      Value: 35 kW
    7. Create: The combustion chamber #3539839
      Value: Closed
    8. Create: Heated area #3539840
      Value: 400 sq.m
    9. Create: Efficiency #3539841
      Value: 91.4 %
    10. Create: Control #3539842
      Value: Electronic
    11. Create: Installation #3539843
      Value: Floor
    12. Create: Mains voltage #3539844
      Value: Single-phase
    13. Create: Peculiarities #3539845
      Value: External control connector
    14. Create: Equipment #3539846
      Value: Display, room thermostat, remote control
    15. Create: Fuel #3539847
      Value: Diesel fuel, waste oil, natural gas, LPG
    16. Create: Natural gas consumption #3539848
      Value: 3.8 cu. m/hour
    17. Create: Nominal pressure of natural gas #3539849
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3539850
      Value: 28 mbar
    19. Create: Max. coolant temperature #3539851
      Value: 85 °С
    20. Create: Hot water capacity at t 25°C #3539852
      Value: 23.33 l/min
    21. Create: Hot water capacity at t 40°C #3539853
      Value: 14.58 l/min
    22. Create: Max. water pressure in the DHW circuit #3539854
      Value: 5 bar
    23. Create: Max. water pressure in the heating circuit #3539855
      Value: 3 bar
    24. Create: Gas connection #3539856
      Value: 1/2"
    25. Create: Heating circuit connection #3539857
      Value: 1¼
    26. Create: Branch pipe for connecting the DHW circuit #3539858
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3539859
      Value: 75/100 mm
    28. Create: Dimensions WxHxD #3539860
      Value: 405x905x680 mm
    29. Create: Weight #3539861
      Value: 97 kg
    30. Create: Additional Information #3539862
      Value: For operation on diesel or waste oil, you must purchase the appropriate burner
    31. Create: Image #6348515
      URL: https://avatars.mds.yandex.net/get-mpic/4448884/img_id2821594451359055916.jpeg/orig
    32. Create: Preview image #6348516
      URL: https://avatars.mds.yandex.net/get-mpic/4448884/img_id2821594451359055916.jpeg/orig
  2. Donny Darko 30 April 2023 08:59:37
    Name: Combined boiler Olympia OLB-350 G-R 35 kW double-circuit; Catalog: Heating boilers