Change history for item: Combined boiler Olympia OLB-250 G-R 25 kW double-circuit

  1. Donny Darko 09 July 2023 08:12:08
    1. Create: Description #3539803
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3539804
      Value: Gas, convection
    3. Create: Burner #3539805
      Value: Gas
    4. Create: Number of circuits #3539806
      Value: Double-circuit
    5. Create: Max. thermal power #3539807
      Value: 25 kW
    6. Create: Max. thermal load #3539808
      Value: 29 kW
    7. Create: The combustion chamber #3539809
      Value: Closed
    8. Create: Heated area #3539810
      Value: 290 sq.m
    9. Create: Efficiency #3539811
      Value: 91 %
    10. Create: Control #3539812
      Value: Electronic
    11. Create: Installation #3539813
      Value: Floor
    12. Create: Mains voltage #3539814
      Value: Single-phase
    13. Create: Peculiarities #3539815
      Value: External control connector
    14. Create: Equipment #3539816
      Value: Display, room thermostat, remote control
    15. Create: Fuel #3539817
      Value: Diesel fuel, waste oil, natural gas, LPG
    16. Create: Natural gas consumption #3539818
      Value: 2.7 cu. m/hour
    17. Create: Nominal pressure of natural gas #3539819
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3539820
      Value: 28 mbar
    19. Create: Max. coolant temperature #3539821
      Value: 85 °С
    20. Create: Hot water capacity at t 25°C #3539822
      Value: 16.67 l/min
    21. Create: Hot water capacity at t 40°C #3539823
      Value: 10.42 l/min
    22. Create: Max. water pressure in the DHW circuit #3539824
      Value: 5 bar
    23. Create: Max. water pressure in the heating circuit #3539825
      Value: 3 bar
    24. Create: Gas connection #3539826
      Value: 1/2"
    25. Create: Heating circuit connection #3539827
      Value: 1¼
    26. Create: Branch pipe for connecting the DHW circuit #3539828
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3539829
      Value: 75/100 mm
    28. Create: Dimensions WxHxD #3539830
      Value: 405x905x680 mm
    29. Create: Weight #3539831
      Value: 82 kg
    30. Create: Additional Information #3539832
      Value: To switch to diesel fuel, it is necessary to install a diesel burner, to switch to used oil - an AL burner
    31. Create: Image #6348513
      URL: https://avatars.mds.yandex.net/get-mpic/3699895/img_id2282057591713362376.jpeg/orig
    32. Create: Preview image #6348514
      URL: https://avatars.mds.yandex.net/get-mpic/3699895/img_id2282057591713362376.jpeg/orig
  2. Donny Darko 30 April 2023 08:59:37
    Name: Combined boiler Olympia OLB-250 G-R 25 kW double-circuit; Catalog: Heating boilers