Change history for item: Gas ROSS AOGV 40D Lux 40 kW double-circuit

  1. Donny Darko 09 July 2023 07:54:59
    1. Create: Description #3535918
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3535919
      Value: Gas, convection
    3. Create: Burner #3535920
      Value: Gas
    4. Create: Number of circuits #3535921
      Value: Double-circuit
    5. Create: Max. thermal power #3535922
      Value: 40 kW
    6. Create: Non-volatile #3535923
      Value: Yes
    7. Create: The combustion chamber #3535924
      Value: Open
    8. Create: Heated area #3535925
      Value: 400 sq.m
    9. Create: Efficiency #3535926
      Value: 93 %
    10. Create: Control #3535927
      Value: Mechanical
    11. Create: Installation #3535928
      Value: Floor
    12. Create: Primary heat exchanger material #3535929
      Value: Steel
    13. Create: Secondary heat exchanger material #3535930
      Value: Copper
    14. Create: Built-in circulation pump #3535931
      Value: No
    15. Create: Built-in expansion tank #3535932
      Value: No
    16. Create: Fuel #3535933
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3535934
      Value: 4.6 cu. m/hour
    18. Create: LPG consumption #3535935
      Value: 3.5 kg/hour
    19. Create: Hot water capacity at t 30°C #3535936
      Value: 7.5 l/min
    20. Create: Max. water pressure in the heating circuit #3535937
      Value: 3 bar
    21. Create: Functions #3535938
      Value: Thermometer
    22. Create: Peculiarities #3535939
      Value: External control connection
    23. Create: Protection #3535940
      Value: Gas control
    24. Create: Gas connection #3535941
      Value: 3/4"
    25. Create: Heating circuit connection #3535942
      Value: 2"
    26. Create: Branch pipe for connecting the DHW circuit #3535943
      Value: 1/2"
    27. Create: Chimney diameter #3535944
      Value: 150 mm
    28. Create: Dimensions WxHxD #3535945
      Value: 600x880x605 mm
    29. Create: Weight #3535946
      Value: 132 kg
    30. Create: Image #6348036
      URL: https://avatars.mds.yandex.net/get-mpic/1525355/img_id3600682591348392144/orig
    31. Create: Preview image #6348037
      URL: https://avatars.mds.yandex.net/get-mpic/1525355/img_id3600682591348392144/orig
  2. Donny Darko 30 April 2023 08:58:41
    Name: Gas ROSS AOGV 40D Lux 40 kW double-circuit; Catalog: Heating boilers