Change history for item: Gas 18VR 18 kW double-circuit

  1. Donny Darko 09 July 2023 07:29:31
    1. Create: Description #3531578
      Value: Type of heating boiler: gas, max. thermal power: 18 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, control: mechanical,
    2. Create: Type of heating boiler #3531579
      Value: Gas, convection
    3. Create: Burner #3531580
      Value: Gas
    4. Create: Number of circuits #3531581
      Value: Double-circuit
    5. Create: Max. thermal power #3531582
      Value: 18 kW
    6. Create: Max. thermal load #3531583
      Value: 19.80 kW
    7. Create: Non-volatile #3531584
      Value: Yes
    8. Create: The combustion chamber #3531585
      Value: Open
    9. Create: Efficiency #3531586
      Value: 91.5 %
    10. Create: Control #3531587
      Value: Mechanical
    11. Create: Installation #3531588
      Value: Floor
    12. Create: Primary heat exchanger material #3531589
      Value: Steel
    13. Create: Secondary heat exchanger material #3531590
      Value: Copper
    14. Create: Peculiarities #3531591
      Value: Thermometer, gas filter
    15. Create: Fuel #3531592
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3531593
      Value: 2.1 cu. m/hour
    17. Create: LPG consumption #3531594
      Value: 0.78 kg/hour
    18. Create: Nominal pressure of natural gas #3531595
      Value: 6.35 - 17.64 mbar
    19. Create: Permissible LPG pressure #3531596
      Value: 35.28 mbar
    20. Create: Heat carrier temperature #3531597
      Value: 40 - 90 °С
    21. Create: Max. water pressure in the DHW circuit #3531598
      Value: 6 bar
    22. Create: Max. water pressure in the heating circuit #3531599
      Value: 1.5 bar
    23. Create: Gas connection #3531600
      Value: 1/2"
    24. Create: Heating circuit connection #3531601
      Value: 2"
    25. Create: Branch pipe for connecting the DHW circuit #3531602
      Value: 1/2"
    26. Create: Chimney diameter #3531603
      Value: 120 mm
    27. Create: Dimensions WxHxD #3531604
      Value: 350x850x497 mm
    28. Create: Weight #3531605
      Value: 6.85 kg
    29. Create: Additional Information #3531606
      Value: KARE automation
    30. Create: Image #6347535
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2805319281500381796/orig
    31. Create: Preview image #6347536
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2805319281500381796/orig
  2. Donny Darko 30 April 2023 08:57:38
    Name: Gas 18VR 18 kW double-circuit; Catalog: Heating boilers