Change history for item: Gas AKGV-23.2 23.2 kW double-circuit

  1. Donny Darko 09 July 2023 06:57:59
    1. Create: Description #3526367
      Value: Type of heating boiler: gas, max. thermal power: 23.20 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, type of combustion chamber: open, control: mechanical, operating principle
    2. Create: Type of heating boiler #3526368
      Value: Gas, convection
    3. Create: Burner #3526369
      Value: Gas
    4. Create: Number of circuits #3526370
      Value: Double-circuit
    5. Create: Max. thermal power #3526371
      Value: 23.20 kW
    6. Create: Non-volatile #3526372
      Value: Yes
    7. Create: The combustion chamber #3526373
      Value: Open
    8. Create: Heated area #3526374
      Value: 232 sq.m
    9. Create: Efficiency #3526375
      Value: 90 %
    10. Create: Control #3526376
      Value: Mechanical
    11. Create: Installation #3526377
      Value: Floor
    12. Create: Primary heat exchanger material #3526378
      Value: Steel
    13. Create: Secondary heat exchanger material #3526379
      Value: Copper
    14. Create: Peculiarities #3526380
      Value: Thermometer
    15. Create: Fuel #3526381
      Value: Natural gas
    16. Create: Natural gas consumption #3526382
      Value: 2.24 cu. m/hour
    17. Create: Nominal pressure of natural gas #3526383
      Value: 6.37 - 12.74 mbar
    18. Create: Heat carrier temperature #3526384
      Value: 40 - 90 °С
    19. Create: Hot water capacity at t 45°C #3526385
      Value: 9 l/min
    20. Create: Max. water pressure in the DHW circuit #3526386
      Value: 6 bar
    21. Create: Max. water pressure in the heating circuit #3526387
      Value: 2 bar
    22. Create: Gas connection #3526388
      Value: 1/2"
    23. Create: Heating circuit connection #3526389
      Value: 2"
    24. Create: Branch pipe for connecting the DHW circuit #3526390
      Value: 1/2"
    25. Create: Chimney diameter #3526391
      Value: 130 mm
    26. Create: Dimensions WxHxD #3526392
      Value: 344x890x462 mm
    27. Create: Weight #3526393
      Value: 55 kg
    28. Create: Additional Information #3526394
      Value: Safety automation TGV
    29. Create: Image #6346896
      URL: https://avatars.mds.yandex.net/get-mpic/4291905/img_id5776474364966335424.jpeg/orig
    30. Create: Image #6346897
      URL: https://avatars.mds.yandex.net/get-mpic/4219828/img_id6183863735981203777.jpeg/orig
    31. Create: Preview image #6346898
      URL: https://avatars.mds.yandex.net/get-mpic/4291905/img_id5776474364966335424.jpeg/orig
  2. Donny Darko 30 April 2023 08:56:19
    Name: Gas AKGV-23.2 23.2 kW double-circuit; Catalog: Heating boilers