Change history for item: FLAMES Eco CODE-32

  1. Donny Darko 08 July 2023 18:25:22
    1. Create: Width #34157
      Value: 660
    2. Create: Height #34158
      Value: 960
    3. Create: Description #3524542
      Value: Type of heating boiler: solid fuel, max. thermal power: 34 kW, number of circuits: single-circuit, placement: floor, fuel: wood briquettes, firewood, coke, peat, peat briquettes, coal, coal briquettes
    4. Create: Type of heating boiler #3524543
      Value: Solid fuel
    5. Create: Number of circuits #3524544
      Value: Single-loop
    6. Create: The principle of operation of a solid fuel boiler #3524545
      Value: Long burning
    7. Create: Combustion chamber type #3524546
      Value: Closed
    8. Create: Primary heat exchanger material #3524547
      Value: Steel
    9. Create: Accommodation #3524548
      Value: Floor
    10. Create: Non-volatile #3524549
      Value: There is
    11. Create: Control #3524550
      Value: Mechanical
    12. Create: Equipment #3524551
      Value: Adjustable gate
    13. Create: Minimum heat output #3524552
      Value: 16 kW
    14. Create: Max. thermal power #3524553
      Value: 34 kW
    15. Create: Minimum heat load #3524554
      Value: 16 kW
    16. Create: Maximum thermal load #3524555
      Value: 34 kW
    17. Create: Efficiency #3524556
      Value: 84 %
    18. Create: Heated area #3524557
      Value: 320 m²
    19. Create: Maximum water pressure in the heating circuit #3524558
      Value: 1.5 bar
    20. Create: Minimum heating medium temperature #3524559
      Value: 55°C
    21. Create: Maximum coolant temperature #3524560
      Value: 95°C
    22. Create: Heating circuit connection #3524561
      Value: 2"
    23. Create: Chimney diameter #3524562
      Value: 150 mm
    24. Create: Burner #3524563
      Value: Can be purchased
    25. Create: Recommended fuel #3524564
      Value: Firewood
    26. Create: Fuel #3524565
      Value: Wood briquettes, firewood, coke, peat, peat briquettes, coal, coal briquettes
    27. Create: Fuel consumption #3524566
      Value: 4.76 kg/h
    28. Create: Depth #3524567
      Value: 860 mm
    29. Create: Weight #3524568
      Value: 221 kg
    30. Create: Heating element for temperature maintenance #3524569
      Value: Optional
    31. Create: The power of heating elements to maintain the temperature #3524570
      Value: 15 kW
    32. Create: Image #6346618
      URL: https://avatars.mds.yandex.net/get-mpic/5304975/img_id8511370749977924561.jpeg/orig
    33. Create: Image #6346619
      URL: https://avatars.mds.yandex.net/get-mpic/5347553/img_id2035961124561422200.jpeg/orig
    34. Create: Image #6346620
      URL: https://avatars.mds.yandex.net/get-mpic/4516625/img_id7895052700337261628.jpeg/orig
    35. Create: Preview image #6346621
      URL: https://avatars.mds.yandex.net/get-mpic/5304975/img_id8511370749977924561.jpeg/orig
  2. Donny Darko 30 April 2023 08:55:50
    Name: FLAMES Eco CODE-32; Catalog: Heating boilers