Change history for item: Daewoo DGB-300MES 34.9 kW dual circuit

  1. Donny Darko 08 July 2023 17:11:37
    1. Create: Description #3514075
      Value: Type of heating boiler: gas, max. heating power: 34.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3514076
      Value: Gas, condensing
    3. Create: Burner #3514077
      Value: Gas
    4. Create: Number of circuits #3514078
      Value: Double-circuit
    5. Create: Thermal power #3514079
      Value: 11.60 - 34.90 kW
    6. Create: The combustion chamber #3514080
      Value: Closed
    7. Create: Heated area #3514081
      Value: 349 sq.m
    8. Create: Efficiency #3514082
      Value: 106.3 %
    9. Create: Control #3514083
      Value: Electronic
    10. Create: Installation #3514084
      Value: Wall-mounted
    11. Create: Mains voltage #3514085
      Value: Single-phase
    12. Create: Peculiarities #3514086
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Equipment #3514087
      Value: Display, remote control
    14. Create: Fuel #3514088
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3514089
      Value: 3.36 cu. m/hour
    16. Create: LPG consumption #3514090
      Value: 2.94 kg/h
    17. Create: Nominal pressure of natural gas #3514091
      Value: 25 mbar
    18. Create: Heat carrier temperature #3514092
      Value: 40 - 85 °С
    19. Create: Temperature in the DHW circuit #3514093
      Value: 35 - 60 °С
    20. Create: Hot water capacity at t 25°C #3514094
      Value: 20 l/min
    21. Create: Hot water capacity at t 40°C #3514095
      Value: 12.5 l/min
    22. Create: Max. water pressure in the DHW circuit #3514096
      Value: 7 bar
    23. Create: Max. water pressure in the heating circuit #3514097
      Value: 2 bar
    24. Create: Gas connection #3514098
      Value: 3/4"
    25. Create: Heating circuit connection #3514099
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3514100
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3514101
      Value: 80/110 mm
    28. Create: Dimensions WxHxD #3514102
      Value: 490x626x365 mm
    29. Create: Weight #3514103
      Value: 38 kg
    30. Create: Image #6344393
      URL: https://avatars.mds.yandex.net/get-mpic/4450422/img_id1273771011337286680.jpeg/orig
    31. Create: Image #6344394
      URL: https://avatars.mds.yandex.net/get-mpic/4334746/img_id7367494222696503862.jpeg/orig
    32. Create: Preview image #6344395
      URL: https://avatars.mds.yandex.net/get-mpic/4450422/img_id1273771011337286680.jpeg/orig
  2. Donny Darko 30 April 2023 08:53:05
    Name: Daewoo DGB-300MES 34.9 kW dual circuit; Catalog: Heating boilers