Change history for item: Gas HydroSta HSG-160SD

  1. Donny Darko 08 July 2023 17:08:25
    1. Create: Description #3513259
      Value: Type of heating boiler: gas, max. heating power: 18.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3513260
      Value: Gas, convection
    3. Create: Burner #3513261
      Value: Gas
    4. Create: Number of circuits #3513262
      Value: Double-circuit
    5. Create: Thermal power #3513263
      Value: 10.50 - 18.60 kW
    6. Create: The combustion chamber #3513264
      Value: Closed
    7. Create: Heated area #3513265
      Value: 150 sq.m
    8. Create: Efficiency #3513266
      Value: 91 %
    9. Create: Control #3513267
      Value: Electronic
    10. Create: Installation #3513268
      Value: Wall-mounted
    11. Create: Mains voltage #3513269
      Value: Single-phase
    12. Create: Peculiarities #3513270
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3513271
      Value: 8 l
    14. Create: Equipment #3513272
      Value: Display, room thermostat, remote control
    15. Create: Fuel #3513273
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3513274
      Value: 1.9 cu. m/hour
    17. Create: LPG consumption #3513275
      Value: 16.7 kg/hour
    18. Create: Nominal pressure of natural gas #3513276
      Value: 10 - 25 mbar
    19. Create: Max. coolant temperature #3513277
      Value: 95 °С
    20. Create: Hot water capacity at t 25°C #3513278
      Value: 13.3 l/min
    21. Create: Hot water capacity at t 40°C #3513279
      Value: 8.3 l/min
    22. Create: Max. water pressure in the heating circuit #3513280
      Value: 3 bar
    23. Create: Gas connection #3513281
      Value: 1/2"
    24. Create: Heating circuit connection #3513282
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3513283
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3513284
      Value: 80/100 mm
    27. Create: Dimensions WxHxD #3513285
      Value: 490x626x242mm
    28. Create: Weight #3513286
      Value: 27 kg
    29. Create: Image #6344287
      URL: https://avatars.mds.yandex.net/get-mpic/1554397/img_id6832472127876344074/orig
    30. Create: Preview image #6344288
      URL: https://avatars.mds.yandex.net/get-mpic/1554397/img_id6832472127876344074/orig
  2. Donny Darko 30 April 2023 08:52:58
    Name: Gas HydroSta HSG-160SD; Catalog: Heating boilers