Change history for item: Combined KSTGV-16 16 kW double-circuit

  1. Donny Darko 09 July 2023 09:10:38
    1. Create: Heat carrier temperature #3551466
      Value: 50 - 90 °C
    2. Create: Max. water pressure in the DHW circuit #3551467
      Value: 6 bar
    3. Create: Branch pipe for connecting the DHW circuit #3551468
      Value: 1/2"
    4. Create: Chimney diameter #3551469
      Value: 140 mm
    5. Create: Image #6349900
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id6046224831208239637/orig
  2. Donny Darko 08 July 2023 16:43:41
    1. Create: Description #3509631
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3509633
      Value: Combined
    3. Create: The principle of operation on solid fuel #3509635
      Value: Classical
    4. Create: Burner #3509637
      Value: Gas
    5. Create: Number of circuits #3509639
      Value: Double-circuit
    6. Create: Max. thermal power #3509641
      Value: 16 kW
    7. Create: Max. thermal load #3509643
      Value: 20 kW
    8. Create: Non-volatile #3509645
      Value: Yes
    9. Create: The combustion chamber #3509647
      Value: Open
    10. Create: Heated area #3509649
      Value: 160 sq.m
    11. Create: Efficiency #3509651
      Value: 87 %
    12. Create: Control #3509653
      Value: Mechanical
    13. Create: Installation #3509655
      Value: Floor
    14. Create: Primary heat exchanger material #3509657
      Value: Steel
    15. Create: Peculiarities #3509658
      Value: Thermometer
    16. Create: Fuel #3509659
      Value: Firewood, natural gas, liquefied gas, peat, coal
    17. Create: Natural gas consumption #3509660
      Value: 2.12 cu. m/hour
    18. Create: Nominal pressure of natural gas #3509661
      Value: 6.35 - 17.64 mbar
    19. Create: Hot water capacity at t 35°C #3509662
      Value: 5.3 l/min
    20. Create: Max. water pressure in the heating circuit #3509663
      Value: 2 bar
    21. Create: Gas connection #3509664
      Value: 1/2"
    22. Create: Heating circuit connection #3509665
      Value: 2"
    23. Create: Dimensions WxHxD #3509666
      Value: 400x920x620 mm
    24. Create: Weight #3509667
      Value: 90 kg
    25. Create: Additional Information #3509668
      Value: Gas burner AGU-T-M
    26. Create: Image #6343526
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id1048890075837251075/orig
    27. Create: Preview image #6343527
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id1048890075837251075/orig
  3. Donny Darko 30 April 2023 08:51:39
    Name: Combined KSTGV-16 16 kW double-circuit; Catalog: Heating boilers