Change history for item: Westen Star Digit 280 Fi 28 kW double circuit

  1. Donny Darko 08 July 2023 13:47:32
    1. Create: Description #3486705
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3486706
      Value: Gas, convection
    3. Create: Burner #3486707
      Value: Gas
    4. Create: Number of circuits #3486708
      Value: Double-circuit
    5. Create: Thermal power #3486709
      Value: 10.40 - 28 kW
    6. Create: The combustion chamber #3486710
      Value: Closed
    7. Create: Efficiency #3486711
      Value: 92.9 %
    8. Create: Control #3486712
      Value: Electronic
    9. Create: Installation #3486713
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3486714
      Value: Copper
    11. Create: Secondary heat exchanger material #3486715
      Value: Stainless steel
    12. Create: Mains voltage #3486716
      Value: Single-phase
    13. Create: Peculiarities #3486717
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3486718
      Value: 10 l
    15. Create: Equipment #3486719
      Value: Display
    16. Create: Fuel #3486720
      Value: Natural gas
    17. Create: Natural gas consumption #3486721
      Value: 2.84 cu. m/hour
    18. Create: Nominal pressure of natural gas #3486722
      Value: 20 mbar
    19. Create: Heat carrier temperature #3486723
      Value: 30 - 85 °С
    20. Create: Temperature in the DHW circuit #3486724
      Value: 35 - 60 °С
    21. Create: Hot water capacity at t 25°C #3486725
      Value: 16 l/min
    22. Create: Max. water pressure in the DHW circuit #3486726
      Value: 8 bar
    23. Create: Max. water pressure in the heating circuit #3486727
      Value: 3 bar
    24. Create: Gas connection #3486728
      Value: 3/4"
    25. Create: Heating circuit connection #3486729
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3486730
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3486731
      Value: 60/100 mm
    28. Create: Connection of a separate chimney diameter 80 mm #3486732
      Value: Yes
    29. Create: Dimensions WxHxD #3486733
      Value: 450x760x345 mm
    30. Create: Weight #3486734
      Value: 40 kg
    31. Create: Image #6337207
      URL: https://avatars.mds.yandex.net/get-mpic/4012265/img_id2158635254381907676.jpeg/orig
    32. Create: Preview image #6337208
      URL: https://avatars.mds.yandex.net/get-mpic/4012265/img_id2158635254381907676.jpeg/orig
  2. Donny Darko 30 April 2023 08:45:02
    Name: Westen Star Digit 280 Fi 28 kW double circuit; Catalog: Heating boilers