      Value: Type of heating boiler: gas, max. heating power: 24.40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    2. Create: Type of heating boiler #3486397
      Value: Gas, convection
    3. Create: Burner #3486398
      Value: Gas
    4. Create: Number of circuits #3486399
      Value: Double-circuit
    5. Create: Thermal power #3486400
      Value: 10.40 - 24.40 kW
    6. Create: Thermal load #3486401
      Value: 11.90 - 27.10 kW
    7. Create: The combustion chamber #3486402
      Value: Open
    8. Create: Efficiency #3486403
      Value: 90.2 %
    9. Create: Control #3486404
      Value: Electronic
    10. Create: Installation #3486405
      Value: Wall-mounted
    11. Create: Mains voltage #3486406
      Value: Single-phase
    12. Create: Peculiarities #3486407
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: The volume of the built-in boiler #3486408
      Value: 40 l
    14. Create: Expansion tank volume #3486409
      Value: 7.5 l
    15. Create: Equipment #3486410
      Value: Built-in boiler, display
    16. Create: Fuel #3486411
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3486412
      Value: 2.87 cu. m/hour
    18. Create: LPG consumption #3486413
      Value: 2.14 kg/h
    19. Create: Nominal pressure of natural gas #3486414
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3486415
      Value: 37 mbar
    21. Create: Heat carrier temperature #3486416
      Value: 30 - 85 °С
    22. Create: Temperature in the DHW circuit #3486417
      Value: 35 - 60 °С
    23. Create: Hot water capacity at t 25°C #3486418
      Value: 14 l/min
    24. Create: Hot water capacity at t 35°C #3486419
      Value: 10 l/min
    25. Create: Max. water pressure in the DHW circuit #3486420
      Value: 8 bar
    26. Create: Max. water pressure in the heating circuit #3486421
      Value: 3 bar
    27. Create: Gas connection #3486422
      Value: 3/4"
    28. Create: Heating circuit connection #3486423
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3486424
      Value: 1/2"
    30. Create: Chimney diameter #3486425
      Value: 140 mm
    31. Create: Dimensions WxHxD #3486426
      Value: 600x950x466mm
    32. Create: Weight #3486427
      Value: 60 kg
    33. Create: Image #6337185
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id5045620079714635064/orig
    34. Create: Preview image #6337186
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id5045620079714635064/orig
  2. Donny Darko 30 April 2023 08:44:58
    Name: Westen Boyler Digit 240/40 i 24.4 kW dual circuit; Catalog: Heating boilers