Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 13:45:34
Create:
Description #3486362
Value: Type of heating boiler: gas, max. thermal power: 28 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3486363
Value: Gas, convection
Create:
Burner #3486364
Value: Gas
Create:
Number of circuits #3486365
Value: Double-circuit
Create:
Thermal power #3486366
Value: 10.40 - 28 kW
Create:
Thermal load #3486367
Value: 11.90 - 30.10 kW
Create:
The combustion chamber #3486368
Value: Closed
Create:
Efficiency #3486369
Value: 93.1 %
Create:
Control #3486370
Value: Electronic
Create:
Installation #3486371
Value: Wall-mounted
Create:
Secondary heat exchanger material #3486372
Value: Stainless steel
Create:
Mains voltage #3486373
Value: Single-phase
Create:
Peculiarities #3486374
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3486375
Value: 60 l
Create:
Expansion tank volume #3486376
Value: 7.5 l
Create:
Equipment #3486377
Value: Built-in boiler, display
Create:
Fuel #3486378
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3486379
Value: 3.18 cu. m/hour
Create:
LPG consumption #3486380
Value: 2.37 kg/h
Create:
Nominal pressure of natural gas #3486381
Value: 20 mbar
Create:
Permissible LPG pressure #3486382
Value: 37 mbar
Create:
Heat carrier temperature #3486383
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3486384
Value: 35 - 60 °С
Create:
Hot water capacity at t 25°C #3486385
Value: 16.1 l/min
Create:
Hot water capacity at t 35°C #3486386
Value: 11.5 l/min
Create:
Max. water pressure in the DHW circuit #3486387
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3486388
Value: 3 bar
Create:
Gas connection #3486389
Value: 3/4"
Create:
Heating circuit connection #3486390
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3486391
Value: 1/2"
Create:
Coaxial chimney diameter #3486392
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3486393
Value: Yes
Create:
Dimensions WxHxD #3486394
Value: 600x950x466mm
Create:
Weight #3486395
Value: 70 kg
Create:
Image #6337183
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id5045620079714635064/orig
Create:
Preview image #6337184
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id5045620079714635064/orig
Donny Darko 30 April 2023 08:44:58
Name: Westen Boyler Digit 280/60 Fi 28 kW dual circuit; Catalog: Heating boilers