Change history for item: Westen Star Digit 240Fi 26.9 kW dual circuit

  1. Donny Darko 08 July 2023 13:44:39
    1. Create: Description #3486184
      Value: Type of heating boiler: gas, max. thermal power: 26.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, combustion chamber type: closed, power type: single-phase, control: electric
    2. Create: Type of heating boiler #3486185
      Value: Gas, convection
    3. Create: Burner #3486186
      Value: Gas
    4. Create: Number of circuits #3486187
      Value: Double-circuit
    5. Create: Thermal power #3486188
      Value: 10.60 - 26.90 kW
    6. Create: The combustion chamber #3486189
      Value: Closed
    7. Create: Efficiency #3486190
      Value: 92.9 %
    8. Create: Control #3486191
      Value: Electronic
    9. Create: Installation #3486192
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3486193
      Value: Copper
    11. Create: Secondary heat exchanger material #3486194
      Value: Stainless steel
    12. Create: Mains voltage #3486195
      Value: Single-phase
    13. Create: Peculiarities #3486196
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3486197
      Value: 8 l
    15. Create: Equipment #3486198
      Value: Display
    16. Create: Fuel #3486199
      Value: Natural gas
    17. Create: Natural gas consumption #3486200
      Value: 2.84 cu. m/hour
    18. Create: Nominal pressure of natural gas #3486201
      Value: 20 mbar
    19. Create: Heat carrier temperature #3486202
      Value: 30 - 85 °С
    20. Create: Temperature in the DHW circuit #3486203
      Value: 35 - 60 °С
    21. Create: Hot water capacity at t 25°C #3486204
      Value: 14.3 l/min
    22. Create: Hot water capacity at t 30°C #3486205
      Value: 10.2 l/min
    23. Create: Max. water pressure in the DHW circuit #3486206
      Value: 8 bar
    24. Create: Max. water pressure in the heating circuit #3486207
      Value: 3 bar
    25. Create: Gas connection #3486208
      Value: 3/4"
    26. Create: Heating circuit connection #3486209
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3486210
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3486211
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3486212
      Value: Yes
    30. Create: Dimensions WxHxD #3486213
      Value: 450x760x345 mm
    31. Create: Weight #3486214
      Value: 38 kg
    32. Create: Image #6337171
      URL: https://avatars.mds.yandex.net/get-mpic/4887838/img_id55267927511730906.jpeg/orig
    33. Create: Preview image #6337172
      URL: https://avatars.mds.yandex.net/get-mpic/4887838/img_id55267927511730906.jpeg/orig
  2. Donny Darko 30 April 2023 08:44:56
    Name: Westen Star Digit 240Fi 26.9 kW dual circuit; Catalog: Heating boilers