Change history for item: Gas Unical ALKON 09 18C 17.4 kW double-circuit

  1. Donny Darko 08 July 2023 13:29:56
    1. Create: Description #3483741
      Value: Type of heating boiler: gas, max. thermal power: 17.40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3483742
      Value: Gas, condensing
    3. Create: Burner #3483743
      Value: Gas
    4. Create: Number of circuits #3483744
      Value: Double-circuit
    5. Create: Thermal power #3483745
      Value: 4.20 - 17.40 kW
    6. Create: Thermal load #3483746
      Value: 4.40 - 18 kW
    7. Create: The combustion chamber #3483747
      Value: Closed
    8. Create: Efficiency #3483748
      Value: 102.1 %
    9. Create: Control #3483749
      Value: Electronic
    10. Create: Installation #3483750
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3483751
      Value: Aluminum
    12. Create: Mains voltage #3483752
      Value: Single-phase
    13. Create: Peculiarities #3483753
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3483754
      Value: 6 l
    15. Create: Equipment #3483755
      Value: Display
    16. Create: Fuel #3483756
      Value: Natural gas
    17. Create: Natural gas consumption #3483757
      Value: 1.9 cu. m/hour
    18. Create: Nominal pressure of natural gas #3483758
      Value: 20 mbar
    19. Create: Heat carrier temperature #3483759
      Value: 30 - 85 °С
    20. Create: Temperature in the DHW circuit #3483760
      Value: 38 - 60 °С
    21. Create: Hot water capacity at t 25°C #3483761
      Value: 10.3 l/min
    22. Create: Hot water capacity at t 30°C #3483762
      Value: 8.6 l/min
    23. Create: Hot water capacity at t 35°C #3483763
      Value: 7.3 l/min
    24. Create: Hot water capacity at t 40°C #3483764
      Value: 6.4 l/min
    25. Create: Hot water capacity at t 45°C #3483765
      Value: 5.7 l/min
    26. Create: Max. water pressure in the DHW circuit #3483766
      Value: 6 bar
    27. Create: Max. water pressure in the heating circuit #3483767
      Value: 3 bar
    28. Create: Gas connection #3483768
      Value: 3/4"
    29. Create: Heating circuit connection #3483769
      Value: 3/4"
    30. Create: Branch pipe for connecting the DHW circuit #3483770
      Value: 1/2"
    31. Create: Coaxial chimney diameter #3483771
      Value: 60/100 mm and 80/125 mm
    32. Create: Connection of a separate chimney diameter 80 mm #3483772
      Value: Yes
    33. Create: Dimensions WxHxD #3483773
      Value: 420x700x310 mm
    34. Create: Weight #3483774
      Value: 33 kg
    35. Create: Image #6336934
      URL: https://avatars.mds.yandex.net/get-mpic/1614201/img_id6720503812461605626/orig
    36. Create: Preview image #6336935
      URL: https://avatars.mds.yandex.net/get-mpic/1614201/img_id6720503812461605626/orig
  2. Donny Darko 30 April 2023 08:44:22
    Name: Gas Unical ALKON 09 18C 17.4 kW double-circuit; Catalog: Heating boilers