Change history for item: Gas Unical KONe C35 32 kW double-circuit

  1. Donny Darko 08 July 2023 13:29:00
    1. Create: Description #3483488
      Value: Type of heating boiler: gas, max. thermal power: 32 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3483489
      Value: Gas, condensing
    3. Create: Burner #3483490
      Value: Gas
    4. Create: Number of circuits #3483491
      Value: Double-circuit
    5. Create: Thermal power #3483492
      Value: 4.30 - 32 kW
    6. Create: Thermal load #3483493
      Value: 4.40 - 33 kW
    7. Create: The combustion chamber #3483494
      Value: Closed
    8. Create: Efficiency #3483495
      Value: 97.3 %
    9. Create: Control #3483496
      Value: Electronic
    10. Create: Installation #3483497
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3483498
      Value: Aluminum
    12. Create: Secondary heat exchanger material #3483499
      Value: Stainless steel
    13. Create: Mains voltage #3483500
      Value: Single-phase
    14. Create: Peculiarities #3483501
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: Expansion tank volume #3483502
      Value: 10 l
    16. Create: Equipment #3483503
      Value: Display
    17. Create: Fuel #3483504
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3483505
      Value: 3.49 cu. m/hour
    19. Create: LPG consumption #3483506
      Value: 2.56 kg/h
    20. Create: Nominal pressure of natural gas #3483507
      Value: 20 mbar
    21. Create: Permissible LPG pressure #3483508
      Value: 37 mbar
    22. Create: Heat carrier temperature #3483509
      Value: 30 - 85 °С
    23. Create: Temperature in the DHW circuit #3483510
      Value: 35 - 60 °С
    24. Create: Hot water capacity at t 25°C #3483511
      Value: 18.3 l/min
    25. Create: Hot water capacity at t 30°C #3483512
      Value: 15.2 l/min
    26. Create: Hot water capacity at t 35°C #3483513
      Value: 13 l/min
    27. Create: Hot water capacity at t 40°C #3483514
      Value: 11.4 l/min
    28. Create: Hot water capacity at t 45°C #3483515
      Value: 10.1 l/min
    29. Create: Max. water pressure in the DHW circuit #3483516
      Value: 6 bar
    30. Create: Max. water pressure in the heating circuit #3483517
      Value: 3 bar
    31. Create: Gas connection #3483518
      Value: 3/4"
    32. Create: Heating circuit connection #3483519
      Value: 3/4"
    33. Create: Branch pipe for connecting the DHW circuit #3483520
      Value: 1/2"
    34. Create: Coaxial chimney diameter #3483521
      Value: 60/100 mm and 80/125 mm
    35. Create: Connection of a separate chimney diameter 80 mm #3483522
      Value: Yes
    36. Create: Dimensions WxHxD #3483523
      Value: 420x700x345mm
    37. Create: Weight #3483524
      Value: 37 kg
    38. Create: Image #6336914
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2302214361829928528/orig
    39. Create: Preview image #6336915
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2302214361829928528/orig
  2. Donny Darko 30 April 2023 08:44:19
    Name: Gas Unical KONe C35 32 kW double-circuit; Catalog: Heating boilers