Change history for item: Gas Unical KON C18 17.4 kW double-circuit

  1. Donny Darko 08 July 2023 13:26:36
    1. Create: Description #3482902
      Value: Type of heating boiler: gas, max. heating power: 17.40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3482903
      Value: Gas, condensing
    3. Create: Burner #3482904
      Value: Gas
    4. Create: Number of circuits #3482905
      Value: Double-circuit
    5. Create: Thermal power #3482906
      Value: 2.90 - 17.40 kW
    6. Create: Thermal load #3482907
      Value: 3 - 18 kW
    7. Create: The combustion chamber #3482908
      Value: Closed
    8. Create: Efficiency #3482909
      Value: 102.3 %
    9. Create: Control #3482910
      Value: Electronic
    10. Create: Installation #3482911
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3482912
      Value: Aluminum
    12. Create: Mains voltage #3482913
      Value: Single-phase
    13. Create: Peculiarities #3482914
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    14. Create: Expansion tank volume #3482915
      Value: 8 l
    15. Create: Equipment #3482916
      Value: Display
    16. Create: Fuel #3482917
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3482918
      Value: 1.9 cu. m/hour
    18. Create: LPG consumption #3482919
      Value: 1.4 kg/hour
    19. Create: Nominal pressure of natural gas #3482920
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3482921
      Value: 37 mbar
    21. Create: Heat carrier temperature #3482922
      Value: 30 - 85 °С
    22. Create: Temperature in the DHW circuit #3482923
      Value: 38 - 60 °С
    23. Create: Hot water capacity at t 25°C #3482924
      Value: 13.2 l/min
    24. Create: Hot water capacity at t 30°C #3482925
      Value: 11 l/min
    25. Create: Hot water capacity at t 35°C #3482926
      Value: 9.44 l/min
    26. Create: Hot water capacity at t 40°C #3482927
      Value: 8.26 l/min
    27. Create: Hot water capacity at t 45°C #3482928
      Value: 7.34 l/min
    28. Create: Max. water pressure in the DHW circuit #3482929
      Value: 6 bar
    29. Create: Max. water pressure in the heating circuit #3482930
      Value: 3 bar
    30. Create: Gas connection #3482931
      Value: 3/4"
    31. Create: Heating circuit connection #3482932
      Value: 3/4"
    32. Create: Branch pipe for connecting the DHW circuit #3482933
      Value: 1/2"
    33. Create: Coaxial chimney diameter #3482934
      Value: 60/100 mm
    34. Create: Connection of a separate chimney diameter 80 mm #3482935
      Value: Yes
    35. Create: Dimensions WxHxD #3482936
      Value: 420x700x345mm
    36. Create: Weight #3482937
      Value: 32.5 kg
    37. Create: Image #6336862
      URL: https://avatars.mds.yandex.net/get-mpic/1859063/img_id434276600052878512/orig
    38. Create: Preview image #6336863
      URL: https://avatars.mds.yandex.net/get-mpic/1859063/img_id434276600052878512/orig
  2. Donny Darko 30 April 2023 08:44:12
    Name: Gas Unical KON C18 17.4 kW double-circuit; Catalog: Heating boilers