Change history for item: Gas Unical KON C35 32 kW double-circuit

  1. Donny Darko 08 July 2023 13:25:46
    1. Create: Description #3482754
      Value: Type of heating boiler: gas, max. thermal power: 32 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3482755
      Value: Gas, condensing
    3. Create: Burner #3482756
      Value: Gas
    4. Create: Number of circuits #3482757
      Value: Double-circuit
    5. Create: Thermal power #3482758
      Value: 4.30 - 32 kW
    6. Create: Thermal load #3482759
      Value: 4.40 - 33 kW
    7. Create: The combustion chamber #3482760
      Value: Closed
    8. Create: Efficiency #3482761
      Value: 102.3 %
    9. Create: Control #3482762
      Value: Electronic
    10. Create: Installation #3482763
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3482764
      Value: Aluminum
    12. Create: Mains voltage #3482765
      Value: Single-phase
    13. Create: Peculiarities #3482766
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    14. Create: Expansion tank volume #3482767
      Value: 8 l
    15. Create: Equipment #3482768
      Value: Display
    16. Create: Fuel #3482769
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3482770
      Value: 3.5 cu. m/hour
    18. Create: LPG consumption #3482771
      Value: 2.56 kg/h
    19. Create: Nominal pressure of natural gas #3482772
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3482773
      Value: 37 mbar
    21. Create: Heat carrier temperature #3482774
      Value: 30 - 85 °С
    22. Create: Temperature in the DHW circuit #3482775
      Value: 38 - 60 °С
    23. Create: Hot water capacity at t 25°C #3482776
      Value: 18.3 l/min
    24. Create: Hot water capacity at t 30°C #3482777
      Value: 15.2 l/min
    25. Create: Hot water capacity at t 35°C #3482778
      Value: 13 l/min
    26. Create: Hot water capacity at t 40°C #3482779
      Value: 11.4 l/min
    27. Create: Hot water capacity at t 45°C #3482780
      Value: 10.1 l/min
    28. Create: Max. water pressure in the DHW circuit #3482781
      Value: 6 bar
    29. Create: Max. water pressure in the heating circuit #3482782
      Value: 3 bar
    30. Create: Gas connection #3482783
      Value: 3/4"
    31. Create: Heating circuit connection #3482784
      Value: 3/4"
    32. Create: Branch pipe for connecting the DHW circuit #3482785
      Value: 1/2"
    33. Create: Coaxial chimney diameter #3482786
      Value: 60/100 mm
    34. Create: Connection of a separate chimney diameter 80 mm #3482787
      Value: Yes
    35. Create: Dimensions WxHxD #3482788
      Value: 420x700x345mm
    36. Create: Weight #3482789
      Value: 36.5 kg
    37. Create: Image #6336852
      URL: https://avatars.mds.yandex.net/get-mpic/1859063/img_id434276600052878512/orig
    38. Create: Preview image #6336853
      URL: https://avatars.mds.yandex.net/get-mpic/1859063/img_id434276600052878512/orig
  2. Donny Darko 30 April 2023 08:44:10
    Name: Gas Unical KON C35 32 kW double-circuit; Catalog: Heating boilers