Change history for item: Gas Unical KON C28 27.2 kW double-circuit

  1. Donny Darko 08 July 2023 13:25:42
    1. Create: Description #3482718
      Value: Type of heating boiler: gas, max. heating power: 27.20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3482719
      Value: Gas, condensing
    3. Create: Burner #3482720
      Value: Gas
    4. Create: Number of circuits #3482721
      Value: Double-circuit
    5. Create: Thermal power #3482722
      Value: 4.30 - 27.20 kW
    6. Create: Thermal load #3482723
      Value: 4.40 - 28 kW
    7. Create: The combustion chamber #3482724
      Value: Closed
    8. Create: Efficiency #3482725
      Value: 103.1 %
    9. Create: Control #3482726
      Value: Electronic
    10. Create: Installation #3482727
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3482728
      Value: Aluminum
    12. Create: Mains voltage #3482729
      Value: Single-phase
    13. Create: Peculiarities #3482730
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    14. Create: Expansion tank volume #3482731
      Value: 8 l
    15. Create: Equipment #3482732
      Value: Display
    16. Create: Fuel #3482733
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3482734
      Value: 2.96 cu. m/hour
    18. Create: LPG consumption #3482735
      Value: 2.17 kg/hour
    19. Create: Nominal pressure of natural gas #3482736
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3482737
      Value: 37 mbar
    21. Create: Heat carrier temperature #3482738
      Value: 30 - 85 °С
    22. Create: Temperature in the DHW circuit #3482739
      Value: 38 - 60 °С
    23. Create: Hot water capacity at t 25°C #3482740
      Value: 15.5 l/min
    24. Create: Hot water capacity at t 30°C #3482741
      Value: 12.9 l/min
    25. Create: Hot water capacity at t 35°C #3482742
      Value: 11.1 l/min
    26. Create: Hot water capacity at t 40°C #3482743
      Value: 9.7 l/min
    27. Create: Hot water capacity at t 45°C #3482744
      Value: 8.6 l/min
    28. Create: Max. water pressure in the DHW circuit #3482745
      Value: 6 bar
    29. Create: Max. water pressure in the heating circuit #3482746
      Value: 3 bar
    30. Create: Gas connection #3482747
      Value: 3/4"
    31. Create: Heating circuit connection #3482748
      Value: 3/4"
    32. Create: Branch pipe for connecting the DHW circuit #3482749
      Value: 1/2"
    33. Create: Coaxial chimney diameter #3482750
      Value: 60/100 mm
    34. Create: Connection of a separate chimney diameter 80 mm #3482751
      Value: Yes
    35. Create: Dimensions WxHxD #3482752
      Value: 420x700x345mm
    36. Create: Weight #3482753
      Value: 36.5 kg
    37. Create: Image #6336850
      URL: https://avatars.mds.yandex.net/get-mpic/1859063/img_id434276600052878512/orig
    38. Create: Preview image #6336851
      URL: https://avatars.mds.yandex.net/get-mpic/1859063/img_id434276600052878512/orig
  2. Donny Darko 30 April 2023 08:44:10
    Name: Gas Unical KON C28 27.2 kW double-circuit; Catalog: Heating boilers