Change history for item: Gas Unical !DEA CS32 32.3 kW double-circuit

  1. Donny Darko 08 July 2023 13:23:55
    1. Create: Description #3482267
      Value: Type of heating boiler: gas, max. heating power: 32.30 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3482268
      Value: Gas, convection
    3. Create: Burner #3482269
      Value: Gas
    4. Create: Number of circuits #3482270
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3482271
      Value: 12.20 - 32.30 kW
    6. Create: Thermal load #3482272
      Value: 13.50 - 34.50 kW
    7. Create: The combustion chamber #3482273
      Value: Closed
    8. Create: Efficiency #3482274
      Value: 93.5 %
    9. Create: Control #3482275
      Value: Electronic
    10. Create: Installation #3482276
      Value: Wall-mounted
    11. Create: Mains voltage #3482277
      Value: Single-phase
    12. Create: Peculiarities #3482278
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3482279
      Value: 10 l
    14. Create: Equipment #3482280
      Value: Display
    15. Create: Fuel #3482281
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3482282
      Value: 3.65 cu. m/hour
    17. Create: LPG consumption #3482283
      Value: 2.68 kg/hour
    18. Create: Nominal pressure of natural gas #3482284
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3482285
      Value: 37 mbar
    20. Create: Heat carrier temperature #3482286
      Value: 45 - 78 °С
    21. Create: Temperature in the DHW circuit #3482287
      Value: 35 - 57 °С
    22. Create: Hot water capacity at t 25°C #3482288
      Value: 17.8 l/min
    23. Create: Hot water capacity at t 30°C #3482289
      Value: 14.9 l/min
    24. Create: Hot water capacity at t 35°C #3482290
      Value: 12.7 l/min
    25. Create: Hot water capacity at t 40°C #3482291
      Value: 11.1 l/min
    26. Create: Hot water capacity at t 45°C #3482292
      Value: 9.9 l/min
    27. Create: Max. water pressure in the DHW circuit #3482293
      Value: 6 bar
    28. Create: Max. water pressure in the heating circuit #3482294
      Value: 3 bar
    29. Create: Gas connection #3482295
      Value: 3/4"
    30. Create: Heating circuit connection #3482296
      Value: 3/4"
    31. Create: Coaxial chimney diameter #3482297
      Value: 60/100 mm
    32. Create: Connection of a separate chimney diameter 80 mm #3482298
      Value: Yes
    33. Create: Dimensions WxHxD #3482299
      Value: 420x700x345mm
    34. Create: Weight #3482300
      Value: 357 kg
    35. Create: Image #6336818
      URL: https://avatars.mds.yandex.net/get-mpic/3698270/img_id4203438469945543855.jpeg/orig
    36. Create: Preview image #6336819
      URL: https://avatars.mds.yandex.net/get-mpic/3698270/img_id4203438469945543855.jpeg/orig
  2. Donny Darko 30 April 2023 08:44:06
    Name: Gas Unical !DEA CS32 32.3 kW double-circuit; Catalog: Heating boilers