Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 13:23:26
Create:
Description #3482142
Value: Type of heating boiler: gas, max. heating power: 22.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
Create:
Type of heating boiler #3482143
Value: Gas, convection
Create:
Burner #3482144
Value: Gas
Create:
Number of circuits #3482145
Value: Double-circuit
Create:
Thermal power #3482146
Value: 9.90 - 22.90 kW
Create:
Thermal load #3482147
Value: 11.50 - 25.50 kW
Create:
The combustion chamber #3482148
Value: Open
Create:
Efficiency #3482149
Value: 91.36 %
Create:
Control #3482150
Value: Electronic
Create:
Installation #3482151
Value: Wall-mounted
Create:
Mains voltage #3482152
Value: Single-phase
Create:
Peculiarities #3482153
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3482154
Value: 6 l
Create:
Equipment #3482155
Value: Display
Create:
Fuel #3482156
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3482157
Value: 2.7 cu. m/hour
Create:
LPG consumption #3482158
Value: 1.98 kg/hour
Create:
Nominal pressure of natural gas #3482159
Value: 20 mbar
Create:
Permissible LPG pressure #3482160
Value: 37 mbar
Create:
Heat carrier temperature #3482161
Value: 45 - 78 °С
Create:
Temperature in the DHW circuit #3482162
Value: 35 - 57 °С
Create:
Hot water capacity at t 25°C #3482163
Value: 14.1 l/min
Create:
Hot water capacity at t 30°C #3482164
Value: 11.7 l/min
Create:
Hot water capacity at t 35°C #3482165
Value: 10 l/min
Create:
Hot water capacity at t 40°C #3482166
Value: 8.8 l/min
Create:
Hot water capacity at t 45°C #3482167
Value: 7.8 l/min
Create:
Max. water pressure in the DHW circuit #3482168
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3482169
Value: 3 bar
Create:
Gas connection #3482170
Value: 3/4"
Create:
Heating circuit connection #3482171
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3482172
Value: 1/2"
Create:
Chimney diameter #3482173
Value: 130 mm
Create:
Dimensions WxHxD #3482174
Value: 420x700x345mm
Create:
Weight #3482175
Value: 286 kg
Create:
Image #6336810
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id7624169337419067420/orig
Create:
Preview image #6336811
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id7624169337419067420/orig
Donny Darko 30 April 2023 08:44:05
Name: Gas Unical !DEA AC23 Plus 22.9 kW double-circuit; Catalog: Heating boilers