Change history for item: Gas Sime Format DGT 25 BF

  1. Donny Darko 08 July 2023 13:12:05
    1. Create: Description #3480298
      Value: Type of heating boiler: gas, max. heating power: 23.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3480299
      Value: Gas, convection
    3. Create: Burner #3480300
      Value: Gas
    4. Create: Number of circuits #3480301
      Value: Double-circuit
    5. Create: Thermal power #3480302
      Value: 7.50 - 23.60 kW
    6. Create: Thermal load #3480303
      Value: 9.20 - 25.50 kW
    7. Create: The combustion chamber #3480304
      Value: Closed
    8. Create: Efficiency #3480305
      Value: 93 %
    9. Create: Control #3480306
      Value: Electronic
    10. Create: Installation #3480307
      Value: Wall-mounted
    11. Create: Mains voltage #3480308
      Value: Single-phase
    12. Create: Peculiarities #3480309
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3480310
      Value: 6 l
    14. Create: Equipment #3480311
      Value: Display
    15. Create: Fuel #3480312
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3480313
      Value: 2.7 cu. m/hour
    17. Create: LPG consumption #3480314
      Value: 2.01 kg/h
    18. Create: Nominal pressure of natural gas #3480315
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3480316
      Value: 37 mbar
    20. Create: Heat carrier temperature #3480317
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3480318
      Value: 10 - 60 °C
    22. Create: Hot water capacity at t 30°C #3480319
      Value: 11.3 l/min
    23. Create: Max. water pressure in the DHW circuit #3480320
      Value: 7 bar
    24. Create: Max. water pressure in the heating circuit #3480321
      Value: 3 bar
    25. Create: Gas connection #3480322
      Value: 3/4"
    26. Create: Heating circuit connection #3480323
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3480324
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3480325
      Value: 60/100 mm
    29. Create: Dimensions WxHxD #3480326
      Value: 400x792x203mm
    30. Create: Weight #3480327
      Value: 30 kg
    31. Create: Image #6336608
      URL: https://avatars.mds.yandex.net/get-mpic/4362876/img_id1079994461549257386.jpeg/orig
    32. Create: Preview image #6336609
      URL: https://avatars.mds.yandex.net/get-mpic/4362876/img_id1079994461549257386.jpeg/orig
  2. Donny Darko 30 April 2023 08:43:42
    Name: Gas Sime Format DGT 25 BF; Catalog: Heating boilers