Change history for item: Gas Sime Format DGT 25 OF

  1. Donny Darko 08 July 2023 13:11:56
    1. Create: Description #3480268
      Value: Type of heating boiler: gas, max. heating power: 22.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3480269
      Value: Gas, convection
    3. Create: Burner #3480270
      Value: Gas
    4. Create: Number of circuits #3480271
      Value: Double-circuit
    5. Create: Thermal power #3480272
      Value: 8.50 - 22.80 kW
    6. Create: Thermal load #3480273
      Value: 10 - 25 kW
    7. Create: The combustion chamber #3480274
      Value: Open
    8. Create: Efficiency #3480275
      Value: 91.3 %
    9. Create: Control #3480276
      Value: Electronic
    10. Create: Installation #3480277
      Value: Wall-mounted
    11. Create: Mains voltage #3480278
      Value: Single-phase
    12. Create: Peculiarities #3480279
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3480280
      Value: 6 l
    14. Create: Equipment #3480281
      Value: Display
    15. Create: Fuel #3480282
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3480283
      Value: 2.61 cu. m/hour
    17. Create: LPG consumption #3480284
      Value: 1.96 kg/h
    18. Create: Nominal pressure of natural gas #3480285
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3480286
      Value: 37 mbar
    20. Create: Heat carrier temperature #3480287
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3480288
      Value: 10 - 60 °C
    22. Create: Hot water capacity at t 30°C #3480289
      Value: 11.3 l/min
    23. Create: Max. water pressure in the DHW circuit #3480290
      Value: 7 bar
    24. Create: Max. water pressure in the heating circuit #3480291
      Value: 3 bar
    25. Create: Gas connection #3480292
      Value: 3/4"
    26. Create: Heating circuit connection #3480293
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3480294
      Value: 1/2"
    28. Create: Chimney diameter #3480295
      Value: 130 mm
    29. Create: Dimensions WxHxD #3480296
      Value: 450x792x290 mm
    30. Create: Weight #3480297
      Value: 26 kg
    31. Create: Image #6336606
      URL: https://avatars.mds.yandex.net/get-mpic/3725687/img_id3914179980323459753.jpeg/orig
    32. Create: Preview image #6336607
      URL: https://avatars.mds.yandex.net/get-mpic/3725687/img_id3914179980323459753.jpeg/orig
  2. Donny Darko 30 April 2023 08:43:42
    Name: Gas Sime Format DGT 25 OF; Catalog: Heating boilers