Change history for item: Gas Sime Metropolis DGT 30 BF

  1. Donny Darko 08 July 2023 13:09:02
    1. Create: Description #3479719
      Value: Type of heating boiler: gas, max. thermal power: 28 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3479720
      Value: Gas, convection
    3. Create: Burner #3479721
      Value: Gas
    4. Create: Number of circuits #3479722
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3479723
      Value: 9 - 28 kW
    6. Create: Thermal load #3479724
      Value: 10.80 - 30 kW
    7. Create: The combustion chamber #3479725
      Value: Closed
    8. Create: Efficiency #3479726
      Value: 93.3 %
    9. Create: Control #3479727
      Value: Electronic
    10. Create: Installation #3479728
      Value: Wall-mounted
    11. Create: Mains voltage #3479729
      Value: Single-phase
    12. Create: Peculiarities #3479730
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3479731
      Value: 6 l
    14. Create: Equipment #3479732
      Value: Display
    15. Create: Fuel #3479733
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3479734
      Value: 3.17 cu. m/hour
    17. Create: LPG consumption #3479735
      Value: 2.37 kg/h
    18. Create: Nominal pressure of natural gas #3479736
      Value: 20 mbar
    19. Create: Heat carrier temperature #3479737
      Value: 40 - 80 °С
    20. Create: Temperature in the DHW circuit #3479738
      Value: 30 - 60 °С
    21. Create: Hot water capacity at t 30°C #3479739
      Value: 14.7 l/min
    22. Create: Max. water pressure in the DHW circuit #3479740
      Value: 7 bar
    23. Create: Max. water pressure in the heating circuit #3479741
      Value: 3 bar
    24. Create: Gas connection #3479742
      Value: 3/4"
    25. Create: Heating circuit connection #3479743
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3479744
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3479745
      Value: 60/100 mm
    28. Create: Dimensions WxHxD #3479746
      Value: 450x700x337mm
    29. Create: Weight #3479747
      Value: 31 kg
    30. Create: Image #6336552
      URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id1847449401958195888.jpeg/orig
    31. Create: Preview image #6336553
      URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id1847449401958195888.jpeg/orig
  2. Donny Darko 30 April 2023 08:43:35
    Name: Gas Sime Metropolis DGT 30 BF; Catalog: Heating boilers