      Value: Type of heating boiler: gas, max. heating power: 23.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3479691
      Value: Gas, convection
    3. Create: Burner #3479692
      Value: Gas
    4. Create: Number of circuits #3479693
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3479694
      Value: 7.50 - 23.70 kW
    6. Create: Thermal load #3479695
      Value: 9.20 - 25.50 kW
    7. Create: The combustion chamber #3479696
      Value: Closed
    8. Create: Efficiency #3479697
      Value: 93 %
    9. Create: Control #3479698
      Value: Electronic
    10. Create: Installation #3479699
      Value: Wall-mounted
    11. Create: Mains voltage #3479700
      Value: Single-phase
    12. Create: Peculiarities #3479701
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3479702
      Value: 6 l
    14. Create: Equipment #3479703
      Value: Display
    15. Create: Fuel #3479704
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3479705
      Value: 2.7 cu. m/hour
    17. Create: LPG consumption #3479706
      Value: 2.01 kg/h
    18. Create: Nominal pressure of natural gas #3479707
      Value: 20 mbar
    19. Create: Heat carrier temperature #3479708
      Value: 40 - 80 °С
    20. Create: Temperature in the DHW circuit #3479709
      Value: 30 - 60 °С
    21. Create: Hot water capacity at t 30°C #3479710
      Value: 11.3 l/min
    22. Create: Max. water pressure in the DHW circuit #3479711
      Value: 7 bar
    23. Create: Max. water pressure in the heating circuit #3479712
      Value: 3 bar
    24. Create: Gas connection #3479713
      Value: 3/4"
    25. Create: Heating circuit connection #3479714
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3479715
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3479716
      Value: 60/100 mm
    28. Create: Dimensions WxHxD #3479717
      Value: 450x700x337mm
    29. Create: Weight #3479718
      Value: 30 kg
    30. Create: Image #6336550
      URL: https://avatars.mds.yandex.net/get-mpic/4219828/img_id1681711389179792373.jpeg/orig
    31. Create: Preview image #6336551
      URL: https://avatars.mds.yandex.net/get-mpic/4219828/img_id1681711389179792373.jpeg/orig
  2. Donny Darko 30 April 2023 08:43:35
    Name: Gas Sime Metropolis DGT 25 BF; Catalog: Heating boilers