      Value: Type of heating boiler: gas, max. heating power: 22.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3479662
      Value: Gas, convection
    3. Create: Burner #3479663
      Value: Gas
    4. Create: Number of circuits #3479664
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3479665
      Value: 8.50 - 22.80 kW
    6. Create: Thermal load #3479666
      Value: 10 - 25 kW
    7. Create: The combustion chamber #3479667
      Value: Open
    8. Create: Efficiency #3479668
      Value: 91.3 %
    9. Create: Control #3479669
      Value: Electronic
    10. Create: Installation #3479670
      Value: Wall-mounted
    11. Create: Mains voltage #3479671
      Value: Single-phase
    12. Create: Peculiarities #3479672
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3479673
      Value: 6 l
    14. Create: Equipment #3479674
      Value: Display
    15. Create: Fuel #3479675
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3479676
      Value: 2.61 cu. m/hour
    17. Create: LPG consumption #3479677
      Value: 1.96 kg/h
    18. Create: Nominal pressure of natural gas #3479678
      Value: 20 mbar
    19. Create: Heat carrier temperature #3479679
      Value: 40 - 80 °С
    20. Create: Temperature in the DHW circuit #3479680
      Value: 30 - 60 °С
    21. Create: Hot water capacity at t 30°C #3479681
      Value: 10.9 l/min
    22. Create: Max. water pressure in the DHW circuit #3479682
      Value: 7 bar
    23. Create: Max. water pressure in the heating circuit #3479683
      Value: 3 bar
    24. Create: Gas connection #3479684
      Value: 3/4"
    25. Create: Heating circuit connection #3479685
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3479686
      Value: 1/2"
    27. Create: Chimney diameter #3479687
      Value: 130 mm
    28. Create: Dimensions WxHxD #3479688
      Value: 450x700x337mm
    29. Create: Weight #3479689
      Value: 26 kg
    30. Create: Image #6336548
      URL: https://avatars.mds.yandex.net/get-mpic/4450422/img_id8369927486894221337.jpeg/orig
    31. Create: Preview image #6336549
      URL: https://avatars.mds.yandex.net/get-mpic/4450422/img_id8369927486894221337.jpeg/orig
  2. Donny Darko 30 April 2023 08:43:34
    Name: Gas Sime Metropolis DGT 25 OF; Catalog: Heating boilers