Change history for item: Gas Nova Florida ORION CONDENSING KB 24 22.8 kW double-circuit

  1. Donny Darko 08 July 2023 12:44:16
    1. Create: Description #3476091
      Value: Type of heating boiler: gas, max. heating power: 22.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3476092
      Value: Gas, condensing
    3. Create: Burner #3476093
      Value: Gas
    4. Create: Number of circuits #3476094
      Value: Double-circuit
    5. Create: Thermal power #3476095
      Value: 2.70 - 22.80 kW
    6. Create: Max. thermal load #3476096
      Value: 23.70 kW
    7. Create: The combustion chamber #3476097
      Value: Closed
    8. Create: Efficiency #3476098
      Value: 105.4 %
    9. Create: Control #3476099
      Value: Electronic
    10. Create: Installation #3476100
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3476101
      Value: Stainless steel
    12. Create: Secondary heat exchanger material #3476102
      Value: Stainless steel
    13. Create: Mains voltage #3476103
      Value: Single-phase
    14. Create: Peculiarities #3476104
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: The volume of the built-in boiler #3476105
      Value: 4.5 l
    16. Create: Expansion tank volume #3476106
      Value: 10 l
    17. Create: Equipment #3476107
      Value: Built-in boiler, display
    18. Create: Fuel #3476108
      Value: Natural gas, liquefied gas
    19. Create: Natural gas consumption #3476109
      Value: 2.51 cu. m/hour
    20. Create: LPG consumption #3476110
      Value: 1.84 kg/hour
    21. Create: Nominal pressure of natural gas #3476111
      Value: 20 mbar
    22. Create: Permissible LPG pressure #3476112
      Value: 37 mbar
    23. Create: Heat carrier temperature #3476113
      Value: 20 - 78 °С
    24. Create: Temperature in the DHW circuit #3476114
      Value: 35 - 65 °С
    25. Create: Hot water capacity at t 30°C #3476115
      Value: 16.2 l/min
    26. Create: Max. water pressure in the DHW circuit #3476116
      Value: 6 bar
    27. Create: Max. water pressure in the heating circuit #3476117
      Value: 3 bar
    28. Create: Gas connection #3476118
      Value: 1/2"
    29. Create: Heating circuit connection #3476119
      Value: 3/4"
    30. Create: Branch pipe for connecting the DHW circuit #3476120
      Value: 1/2"
    31. Create: Coaxial chimney diameter #3476121
      Value: 60/100 mm and 80/125 mm
    32. Create: Dimensions WxHxD #3476122
      Value: 580x861x402 mm
    33. Create: Weight #3476123
      Value: 615 kg
    34. Create: Additional Information #3476124
      Value: DHW expansion tank with a volume of 2 liters
    35. Create: Image #6336078
      URL: https://avatars.mds.yandex.net/get-mpic/1901070/img_id3197147711964463586/orig
    36. Create: Preview image #6336079
      URL: https://avatars.mds.yandex.net/get-mpic/1901070/img_id3197147711964463586/orig
  2. Donny Darko 30 April 2023 08:42:29
    Name: Gas Nova Florida ORION CONDENSING KB 24 22.8 kW double-circuit; Catalog: Heating boilers