Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 12:39:58
Create:
Description #3475063
Value: Type of heating boiler: gas, max. heating power: 29.40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3475064
Value: Gas, condensing
Create:
Burner #3475065
Value: Gas
Create:
Number of circuits #3475066
Value: Double-circuit
Create:
Thermal power #3475067
Value: 3.90 - 29.40 kW
Create:
Max. thermal load #3475068
Value: 30.40 kW
Create:
The combustion chamber #3475069
Value: Closed
Create:
Efficiency #3475070
Value: 105.8 %
Create:
Control #3475071
Value: Electronic
Create:
Installation #3475072
Value: Wall-mounted
Create:
Primary heat exchanger material #3475073
Value: Stainless steel
Create:
Secondary heat exchanger material #3475074
Value: Stainless steel
Create:
Mains voltage #3475075
Value: Single-phase
Create:
Peculiarities #3475076
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3475077
Value: 4.5 l
Create:
Expansion tank volume #3475078
Value: 10 l
Create:
Equipment #3475079
Value: Built-in boiler, display
Create:
Fuel #3475080
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3475081
Value: 3.22 cu. m/hour
Create:
LPG consumption #3475082
Value: 2.36 kg/h
Create:
Nominal pressure of natural gas #3475083
Value: 20 mbar
Create:
Permissible LPG pressure #3475084
Value: 37 mbar
Create:
Heat carrier temperature #3475085
Value: 20 - 78 °С
Create:
Temperature in the DHW circuit #3475086
Value: 35 - 65 °С
Create:
Hot water capacity at t 30°C #3475087
Value: 19.5 l/min
Create:
Max. water pressure in the DHW circuit #3475088
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3475089
Value: 3 bar
Create:
Gas connection #3475090
Value: 1/2"
Create:
Heating circuit connection #3475091
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3475092
Value: 1/2"
Create:
Coaxial chimney diameter #3475093
Value: 60/100 mm and 80/125 mm
Create:
Dimensions WxHxD #3475094
Value: 580x861x402 mm
Create:
Weight #3475095
Value: 66.5 kg
Create:
Additional Information #3475096
Value: DHW expansion tank with a volume of 2 liters
Create:
Image #6335982
URL: https://avatars.mds.yandex.net/get-mpic/1901070/img_id3197147711964463586/orig
Create:
Preview image #6335983
URL: https://avatars.mds.yandex.net/get-mpic/1901070/img_id3197147711964463586/orig
Donny Darko 30 April 2023 08:42:29
Name: Gas Nova Florida ORION CONDENSING KB 32 29.4 kW double-circuit; Catalog: Heating boilers