Change history for item: Gas Nova Florida ORION CONDENSING KB 32 29.4 kW double-circuit

  1. Donny Darko 08 July 2023 12:39:58
    1. Create: Description #3475063
      Value: Type of heating boiler: gas, max. heating power: 29.40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3475064
      Value: Gas, condensing
    3. Create: Burner #3475065
      Value: Gas
    4. Create: Number of circuits #3475066
      Value: Double-circuit
    5. Create: Thermal power #3475067
      Value: 3.90 - 29.40 kW
    6. Create: Max. thermal load #3475068
      Value: 30.40 kW
    7. Create: The combustion chamber #3475069
      Value: Closed
    8. Create: Efficiency #3475070
      Value: 105.8 %
    9. Create: Control #3475071
      Value: Electronic
    10. Create: Installation #3475072
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3475073
      Value: Stainless steel
    12. Create: Secondary heat exchanger material #3475074
      Value: Stainless steel
    13. Create: Mains voltage #3475075
      Value: Single-phase
    14. Create: Peculiarities #3475076
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: The volume of the built-in boiler #3475077
      Value: 4.5 l
    16. Create: Expansion tank volume #3475078
      Value: 10 l
    17. Create: Equipment #3475079
      Value: Built-in boiler, display
    18. Create: Fuel #3475080
      Value: Natural gas, liquefied gas
    19. Create: Natural gas consumption #3475081
      Value: 3.22 cu. m/hour
    20. Create: LPG consumption #3475082
      Value: 2.36 kg/h
    21. Create: Nominal pressure of natural gas #3475083
      Value: 20 mbar
    22. Create: Permissible LPG pressure #3475084
      Value: 37 mbar
    23. Create: Heat carrier temperature #3475085
      Value: 20 - 78 °С
    24. Create: Temperature in the DHW circuit #3475086
      Value: 35 - 65 °С
    25. Create: Hot water capacity at t 30°C #3475087
      Value: 19.5 l/min
    26. Create: Max. water pressure in the DHW circuit #3475088
      Value: 6 bar
    27. Create: Max. water pressure in the heating circuit #3475089
      Value: 3 bar
    28. Create: Gas connection #3475090
      Value: 1/2"
    29. Create: Heating circuit connection #3475091
      Value: 3/4"
    30. Create: Branch pipe for connecting the DHW circuit #3475092
      Value: 1/2"
    31. Create: Coaxial chimney diameter #3475093
      Value: 60/100 mm and 80/125 mm
    32. Create: Dimensions WxHxD #3475094
      Value: 580x861x402 mm
    33. Create: Weight #3475095
      Value: 66.5 kg
    34. Create: Additional Information #3475096
      Value: DHW expansion tank with a volume of 2 liters
    35. Create: Image #6335982
      URL: https://avatars.mds.yandex.net/get-mpic/1901070/img_id3197147711964463586/orig
    36. Create: Preview image #6335983
      URL: https://avatars.mds.yandex.net/get-mpic/1901070/img_id3197147711964463586/orig
  2. Donny Darko 30 April 2023 08:42:29
    Name: Gas Nova Florida ORION CONDENSING KB 32 29.4 kW double-circuit; Catalog: Heating boilers