Change history for item: Gas Nova Florida VIRGO CONDENSING KC 32 29.4 kW double-circuit

  1. Donny Darko 08 July 2023 12:39:54
    1. Create: Description #3475026
      Value: Type of heating boiler: gas, max. heating power: 29.40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3475027
      Value: Gas, condensing
    3. Create: Burner #3475028
      Value: Gas
    4. Create: Number of circuits #3475029
      Value: Double-circuit
    5. Create: Thermal power #3475030
      Value: 3.90 - 29.40 kW
    6. Create: Max. thermal load #3475031
      Value: 30.40 kW
    7. Create: The combustion chamber #3475032
      Value: Closed
    8. Create: Efficiency #3475033
      Value: 106.2 %
    9. Create: Control #3475034
      Value: Electronic
    10. Create: Installation #3475035
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3475036
      Value: Stainless steel
    12. Create: Mains voltage #3475037
      Value: Single-phase
    13. Create: Peculiarities #3475038
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3475039
      Value: 10 l
    15. Create: Equipment #3475040
      Value: Display
    16. Create: Fuel #3475041
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3475042
      Value: 3.21 cu. m/hour
    18. Create: LPG consumption #3475043
      Value: 2.36 kg/h
    19. Create: Nominal pressure of natural gas #3475044
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3475045
      Value: 37 mbar
    21. Create: Heat carrier temperature #3475046
      Value: 20 - 83 °C
    22. Create: Temperature in the DHW circuit #3475047
      Value: 35 - 57 °С
    23. Create: Hot water capacity at t 25°C #3475048
      Value: 19.6 l/min
    24. Create: Hot water capacity at t 30°C #3475049
      Value: 16.2 l/min
    25. Create: Hot water capacity at t 35°C #3475050
      Value: 14 l/min
    26. Create: Hot water capacity at t 40°C #3475051
      Value: 12.2 l/min
    27. Create: Hot water capacity at t 45°C #3475052
      Value: 10.9 l/min
    28. Create: Max. water pressure in the DHW circuit #3475053
      Value: 6 bar
    29. Create: Max. water pressure in the heating circuit #3475054
      Value: 3 bar
    30. Create: Gas connection #3475055
      Value: 1/2"
    31. Create: Heating circuit connection #3475056
      Value: 3/4"
    32. Create: Branch pipe for connecting the DHW circuit #3475057
      Value: 1/2"
    33. Create: Coaxial chimney diameter #3475058
      Value: 60/100 mm
    34. Create: Connection of a separate chimney diameter 80 mm #3475059
      Value: Yes
    35. Create: Dimensions WxHxD #3475060
      Value: 420x750x315 mm
    36. Create: Weight #3475061
      Value: 38 kg
    37. Create: Additional Information #3475062
      Value: Touch control panel; multifunctional relay for connection of zone valves and control of solar collector system
    38. Create: Image #6335980
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id5374115160890303929/orig
    39. Create: Preview image #6335981
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id5374115160890303929/orig
  2. Donny Darko 30 April 2023 08:42:29
    Name: Gas Nova Florida VIRGO CONDENSING KC 32 29.4 kW double-circuit; Catalog: Heating boilers