Change history for item: Gas Nova Florida VIRGO CONDENSING KC 28 25.4 kW double-circuit

  1. Donny Darko 08 July 2023 12:39:49
    1. Create: Description #3474989
      Value: Type of heating boiler: gas, max. heating power: 25.40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3474990
      Value: Gas, condensing
    3. Create: Burner #3474991
      Value: Gas
    4. Create: Number of circuits #3474992
      Value: Double-circuit
    5. Create: Thermal power #3474993
      Value: 3 - 25.40 kW
    6. Create: Max. thermal load #3474994
      Value: 26.40 kW
    7. Create: The combustion chamber #3474995
      Value: Closed
    8. Create: Efficiency #3474996
      Value: 105.5 %
    9. Create: Control #3474997
      Value: Electronic
    10. Create: Installation #3474998
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3474999
      Value: Stainless steel
    12. Create: Mains voltage #3475000
      Value: Single-phase
    13. Create: Peculiarities #3475001
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3475002
      Value: 10 l
    15. Create: Equipment #3475003
      Value: Display
    16. Create: Fuel #3475004
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3475005
      Value: 2.8 cu. m/hour
    18. Create: LPG consumption #3475006
      Value: 2.05 kg/hour
    19. Create: Nominal pressure of natural gas #3475007
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3475008
      Value: 37 mbar
    21. Create: Heat carrier temperature #3475009
      Value: 20 - 83 °C
    22. Create: Temperature in the DHW circuit #3475010
      Value: 35 - 57 °С
    23. Create: Hot water capacity at t 25°C #3475011
      Value: 18.6 l/min
    24. Create: Hot water capacity at t 30°C #3475012
      Value: 15.5 l/min
    25. Create: Hot water capacity at t 35°C #3475013
      Value: 13.3 l/min
    26. Create: Hot water capacity at t 40°C #3475014
      Value: 11.6 l/min
    27. Create: Hot water capacity at t 45°C #3475015
      Value: 10.3 l/min
    28. Create: Max. water pressure in the DHW circuit #3475016
      Value: 6 bar
    29. Create: Max. water pressure in the heating circuit #3475017
      Value: 3 bar
    30. Create: Gas connection #3475018
      Value: 1/2"
    31. Create: Heating circuit connection #3475019
      Value: 3/4"
    32. Create: Branch pipe for connecting the DHW circuit #3475020
      Value: 1/2"
    33. Create: Coaxial chimney diameter #3475021
      Value: 60/100 mm
    34. Create: Connection of a separate chimney diameter 80 mm #3475022
      Value: Yes
    35. Create: Dimensions WxHxD #3475023
      Value: 420x750x315 mm
    36. Create: Weight #3475024
      Value: 32 kg
    37. Create: Additional Information #3475025
      Value: Touch control panel; multifunctional relay for connection of zone valves and control of solar collector system
    38. Create: Image #6335978
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id5374115160890303929/orig
    39. Create: Preview image #6335979
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id5374115160890303929/orig
  2. Donny Darko 30 April 2023 08:42:28
    Name: Gas Nova Florida VIRGO CONDENSING KC 28 25.4 kW double-circuit; Catalog: Heating boilers