Change history for item: Gas Nova Florida VIRGO CONDENSING KC 24 22.9 kW double-circuit

  1. Donny Darko 08 July 2023 12:39:46
    1. Create: Description #3474952
      Value: Type of heating boiler: gas, max. heating power: 22.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3474953
      Value: Gas, condensing
    3. Create: Burner #3474954
      Value: Gas
    4. Create: Number of circuits #3474955
      Value: Double-circuit
    5. Create: Thermal power #3474956
      Value: 2.70 - 22.90 kW
    6. Create: Max. thermal load #3474957
      Value: 23.70 kW
    7. Create: The combustion chamber #3474958
      Value: Closed
    8. Create: Efficiency #3474959
      Value: 105.1 %
    9. Create: Control #3474960
      Value: Electronic
    10. Create: Installation #3474961
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3474962
      Value: Stainless steel
    12. Create: Mains voltage #3474963
      Value: Single-phase
    13. Create: Peculiarities #3474964
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3474965
      Value: 10 l
    15. Create: Equipment #3474966
      Value: Display
    16. Create: Fuel #3474967
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3474968
      Value: 2.51 cu. m/hour
    18. Create: LPG consumption #3474969
      Value: 1.84 kg/hour
    19. Create: Nominal pressure of natural gas #3474970
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3474971
      Value: 37 mbar
    21. Create: Heat carrier temperature #3474972
      Value: 20 - 83 °C
    22. Create: Temperature in the DHW circuit #3474973
      Value: 35 - 57 °С
    23. Create: Hot water capacity at t 25°C #3474974
      Value: 16.1 l/min
    24. Create: Hot water capacity at t 30°C #3474975
      Value: 13.4 l/min
    25. Create: Hot water capacity at t 35°C #3474976
      Value: 11.5 l/min
    26. Create: Hot water capacity at t 40°C #3474977
      Value: 10 l/min
    27. Create: Hot water capacity at t 45°C #3474978
      Value: 8.9 l/min
    28. Create: Max. water pressure in the DHW circuit #3474979
      Value: 6 bar
    29. Create: Max. water pressure in the heating circuit #3474980
      Value: 3 bar
    30. Create: Gas connection #3474981
      Value: 1/2"
    31. Create: Heating circuit connection #3474982
      Value: 3/4"
    32. Create: Branch pipe for connecting the DHW circuit #3474983
      Value: 1/2"
    33. Create: Coaxial chimney diameter #3474984
      Value: 60/100 mm
    34. Create: Connection of a separate chimney diameter 80 mm #3474985
      Value: Yes
    35. Create: Dimensions WxHxD #3474986
      Value: 420x750x315 mm
    36. Create: Weight #3474987
      Value: 305 kg
    37. Create: Additional Information #3474988
      Value: Touch control panel; multifunctional relay for connection of zone valves and control of solar collector system
    38. Create: Image #6335976
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id5374115160890303929/orig
    39. Create: Preview image #6335977
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id5374115160890303929/orig
  2. Donny Darko 30 April 2023 08:42:28
    Name: Gas Nova Florida VIRGO CONDENSING KC 24 22.9 kW double-circuit; Catalog: Heating boilers