Donny Darko 08 July 2023 12:39:43
Create:
Description #3474914
Value: Type of heating boiler: gas, max. heating power: 29.40 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3474915
Value: Gas, condensing
Create:
Burner #3474916
Value: Gas
Create:
Number of circuits #3474917
Value: Double-circuit
Create:
Thermal power #3474918
Value: 3.90 - 29.40 kW
Create:
Max. thermal load #3474919
Value: 30.40 kW
Create:
The combustion chamber #3474920
Value: Closed
Create:
Efficiency #3474921
Value: 106.2 %
Create:
Control #3474922
Value: Electronic
Create:
Installation #3474923
Value: Floor
Create:
Primary heat exchanger material #3474924
Value: Stainless steel
Create:
Mains voltage #3474925
Value: Single-phase
Create:
Peculiarities #3474926
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3474927
Value: 130 l
Create:
Expansion tank volume #3474928
Value: 10 l
Create:
Equipment #3474929
Value: Built-in boiler, display, room thermostat
Create:
Fuel #3474930
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3474931
Value: 3.22 cu. m/hour
Create:
LPG consumption #3474932
Value: 2.36 kg/h
Create:
Nominal pressure of natural gas #3474933
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3474934
Value: 37 mbar
Create:
Heat carrier temperature #3474935
Value: 20 - 83 °C
Create:
Temperature in the DHW circuit #3474936
Value: 35 - 65 °С
Create:
Hot water capacity at t 25°C #3474937
Value: 28.1 l/min
Create:
Hot water capacity at t 30°C #3474938
Value: 23.4 l/min
Create:
Hot water capacity at t 35°C #3474939
Value: 20.1 l/min
Create:
Hot water capacity at t 40°C #3474940
Value: 17.6 l/min
Create:
Hot water capacity at t 45°C #3474941
Value: 15.6 l/min
Create:
Max. water pressure in the DHW circuit #3474942
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3474943
Value: 3 bar
Create:
Gas connection #3474944
Value: 1/2"
Create:
Heating circuit connection #3474945
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3474946
Value: 3/4"
Create:
Coaxial chimney diameter #3474947
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3474948
Value: Yes
Create:
Dimensions WxHxD #3474949
Value: 600x1857x645mm
Create:
Weight #3474950
Value: 162 kg
Create:
Additional Information #3474951
Value: Touchscreen; with 2 built-in sets of high temperature and low temperature zones
Create:
Image #6335974