Change history for item: Liquid fuel Nova Florida LYRA RTFD 43 VA 43 kW single circuit

  1. Donny Darko 08 July 2023 12:38:09
    1. Create: Description #3474457
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3474458
      Value: Liquid fuel, classic
    3. Create: Burner #3474459
      Value: Liquid fuel
    4. Create: Number of circuits #3474460
      Value: Single-loop
    5. Create: Max. thermal power #3474461
      Value: 43 kW
    6. Create: Max. thermal load #3474462
      Value: 47.20 kW
    7. Create: The combustion chamber #3474463
      Value: Closed
    8. Create: Efficiency #3474464
      Value: 91 %
    9. Create: Control #3474465
      Value: Electronic
    10. Create: Installation #3474466
      Value: Floor
    11. Create: Primary heat exchanger material #3474467
      Value: Cast iron
    12. Create: Mains voltage #3474468
      Value: Single-phase
    13. Create: Peculiarities #3474469
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3474470
      Value: 12 l
    15. Create: Equipment #3474471
      Value: Display
    16. Create: Fuel #3474472
      Value: Diesel fuel
    17. Create: Fuel consumption #3474473
      Value: 3.98 kg/h
    18. Create: Heat carrier temperature #3474474
      Value: 50 - 82 °С
    19. Create: Max. water pressure in the heating circuit #3474475
      Value: 3 bar
    20. Create: Heating circuit connection #3474476
      Value: 1"
    21. Create: Chimney diameter #3474477
      Value: 120 mm
    22. Create: Connection of a separate chimney diameter 80 mm #3474478
      Value: Yes
    23. Create: Dimensions WxHxD #3474479
      Value: 600x875x800 mm
    24. Create: Weight #3474480
      Value: 232 kg
    25. Create: Additional Information #3474481
      Value: Filter for diesel fuel; the presence of a low-temperature and high-temperature zone
    26. Create: Image #6335934
      URL: https://avatars.mds.yandex.net/get-mpic/4101287/img_id8518910173645601007.jpeg/orig
    27. Create: Preview image #6335935
      URL: https://avatars.mds.yandex.net/get-mpic/4101287/img_id8518910173645601007.jpeg/orig
  2. Donny Darko 30 April 2023 08:42:21
    Name: Liquid fuel Nova Florida LYRA RTFD 43 VA 43 kW single circuit; Catalog: Heating boilers