Change history for item: Liquid fuel Nova Florida LYRA BTFD 33 33 kW double-circuit

  1. Donny Darko 08 July 2023 12:36:11
    1. Create: Description #3474104
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3474105
      Value: Liquid fuel, classic
    3. Create: Burner #3474106
      Value: Liquid fuel
    4. Create: Number of circuits #3474107
      Value: Double-circuit
    5. Create: Max. thermal power #3474108
      Value: 33 kW
    6. Create: Max. thermal load #3474109
      Value: 36.30 kW
    7. Create: The combustion chamber #3474110
      Value: Closed
    8. Create: Efficiency #3474111
      Value: 91 %
    9. Create: Control #3474112
      Value: Electronic
    10. Create: Installation #3474113
      Value: Floor
    11. Create: Primary heat exchanger material #3474114
      Value: Cast iron
    12. Create: Mains voltage #3474115
      Value: Single-phase
    13. Create: Peculiarities #3474116
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: The volume of the built-in boiler #3474117
      Value: 130 l
    15. Create: Expansion tank volume #3474118
      Value: 12 l
    16. Create: Equipment #3474119
      Value: Built-in boiler
    17. Create: Fuel #3474120
      Value: Diesel fuel
    18. Create: Fuel consumption #3474121
      Value: 3.06 kg/hour
    19. Create: Heat carrier temperature #3474122
      Value: 50 - 82 °С
    20. Create: Temperature in the DHW circuit #3474123
      Value: 35 - 57 °С
    21. Create: Hot water capacity at t 30°C #3474124
      Value: 25 l/min
    22. Create: Max. water pressure in the DHW circuit #3474125
      Value: 7 bar
    23. Create: Max. water pressure in the heating circuit #3474126
      Value: 3 bar
    24. Create: Heating circuit connection #3474127
      Value: 1"
    25. Create: Branch pipe for connecting the DHW circuit #3474128
      Value: 3/4"
    26. Create: Chimney diameter #3474129
      Value: 120 mm
    27. Create: Connection of a separate chimney diameter 80 mm #3474130
      Value: Yes
    28. Create: Dimensions WxHxD #3474131
      Value: 600x1600x800mm
    29. Create: Weight #3474132
      Value: 272 kg
    30. Create: Additional Information #3474133
      Value: DHW expansion tank: 5 liters; DHW circulation pump; safety valve of the DHW circuit; diesel fuel filter
    31. Create: Image #6335906
      URL: https://avatars.mds.yandex.net/get-mpic/3765589/img_id1750399588722478295.jpeg/orig
    32. Create: Preview image #6335907
      URL: https://avatars.mds.yandex.net/get-mpic/3765589/img_id1750399588722478295.jpeg/orig
  2. Donny Darko 30 April 2023 08:42:17
    Name: Liquid fuel Nova Florida LYRA BTFD 33 33 kW double-circuit; Catalog: Heating boilers