Change history for item: Liquid fuel Nova Florida LYRA BTFD 23 24 kW double-circuit

  1. Donny Darko 08 July 2023 12:35:46
    1. Create: Description #3474014
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3474015
      Value: Liquid fuel, classic
    3. Create: Burner #3474016
      Value: Liquid fuel
    4. Create: Number of circuits #3474017
      Value: Double-circuit
    5. Create: Max. thermal power #3474018
      Value: 24 kW
    6. Create: Max. thermal load #3474019
      Value: 26.60 kW
    7. Create: The combustion chamber #3474020
      Value: Closed
    8. Create: Efficiency #3474021
      Value: 90 %
    9. Create: Control #3474022
      Value: Electronic
    10. Create: Installation #3474023
      Value: Floor
    11. Create: Primary heat exchanger material #3474024
      Value: Cast iron
    12. Create: Mains voltage #3474025
      Value: Single-phase
    13. Create: Peculiarities #3474026
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: The volume of the built-in boiler #3474027
      Value: 130 l
    15. Create: Expansion tank volume #3474028
      Value: 12 l
    16. Create: Equipment #3474029
      Value: Built-in boiler
    17. Create: Fuel #3474030
      Value: Diesel fuel
    18. Create: Fuel consumption #3474031
      Value: 2.44 kg/hour
    19. Create: Heat carrier temperature #3474032
      Value: 50 - 82 °С
    20. Create: Temperature in the DHW circuit #3474033
      Value: 35 - 57 °С
    21. Create: Hot water capacity at t 30°C #3474034
      Value: 21.5 l/min
    22. Create: Max. water pressure in the DHW circuit #3474035
      Value: 7 bar
    23. Create: Max. water pressure in the heating circuit #3474036
      Value: 3 bar
    24. Create: Heating circuit connection #3474037
      Value: 1"
    25. Create: Branch pipe for connecting the DHW circuit #3474038
      Value: 3/4"
    26. Create: Chimney diameter #3474039
      Value: 120 mm
    27. Create: Connection of a separate chimney diameter 80 mm #3474040
      Value: Yes
    28. Create: Dimensions WxHxD #3474041
      Value: 600x1600x800mm
    29. Create: Weight #3474042
      Value: 244.2 kg
    30. Create: Additional Information #3474043
      Value: DHW expansion tank: 5 liters; DHW circulation pump; safety valve of the DHW circuit; diesel fuel filter
    31. Create: Image #6335900
      URL: https://avatars.mds.yandex.net/get-mpic/3721790/img_id3156696248684587545.jpeg/orig
    32. Create: Preview image #6335901
      URL: https://avatars.mds.yandex.net/get-mpic/3721790/img_id3156696248684587545.jpeg/orig
  2. Donny Darko 30 April 2023 08:42:16
    Name: Liquid fuel Nova Florida LYRA BTFD 23 24 kW double-circuit; Catalog: Heating boilers