Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 12:35:46
Create:
Description #3474014
Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
Create:
Type of heating boiler #3474015
Value: Liquid fuel, classic
Create:
Burner #3474016
Value: Liquid fuel
Create:
Number of circuits #3474017
Value: Double-circuit
Create:
Max. thermal power #3474018
Value: 24 kW
Create:
Max. thermal load #3474019
Value: 26.60 kW
Create:
The combustion chamber #3474020
Value: Closed
Create:
Efficiency #3474021
Value: 90 %
Create:
Control #3474022
Value: Electronic
Create:
Installation #3474023
Value: Floor
Create:
Primary heat exchanger material #3474024
Value: Cast iron
Create:
Mains voltage #3474025
Value: Single-phase
Create:
Peculiarities #3474026
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3474027
Value: 130 l
Create:
Expansion tank volume #3474028
Value: 12 l
Create:
Equipment #3474029
Value: Built-in boiler
Create:
Fuel #3474030
Value: Diesel fuel
Create:
Fuel consumption #3474031
Value: 2.44 kg/hour
Create:
Heat carrier temperature #3474032
Value: 50 - 82 °С
Create:
Temperature in the DHW circuit #3474033
Value: 35 - 57 °С
Create:
Hot water capacity at t 30°C #3474034
Value: 21.5 l/min
Create:
Max. water pressure in the DHW circuit #3474035
Value: 7 bar
Create:
Max. water pressure in the heating circuit #3474036
Value: 3 bar
Create:
Heating circuit connection #3474037
Value: 1"
Create:
Branch pipe for connecting the DHW circuit #3474038
Value: 3/4"
Create:
Chimney diameter #3474039
Value: 120 mm
Create:
Connection of a separate chimney diameter 80 mm #3474040
Value: Yes
Create:
Dimensions WxHxD #3474041
Value: 600x1600x800mm
Create:
Weight #3474042
Value: 244.2 kg
Create:
Additional Information #3474043
Value: DHW expansion tank: 5 liters; DHW circulation pump; safety valve of the DHW circuit; diesel fuel filter
Create:
Image #6335900
URL: https://avatars.mds.yandex.net/get-mpic/3721790/img_id3156696248684587545.jpeg/orig
Create:
Preview image #6335901
URL: https://avatars.mds.yandex.net/get-mpic/3721790/img_id3156696248684587545.jpeg/orig
Donny Darko 30 April 2023 08:42:16
Name: Liquid fuel Nova Florida LYRA BTFD 23 24 kW double-circuit; Catalog: Heating boilers