Change history for item: Liquid fuel Nova Florida LYRA BTF 43 V 43 kW double-circuit

  1. Donny Darko 08 July 2023 12:35:43
    1. Create: Description #3473985
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3473986
      Value: Liquid fuel, classic
    3. Create: Burner #3473987
      Value: Liquid fuel
    4. Create: Number of circuits #3473988
      Value: Double-circuit
    5. Create: Max. thermal power #3473989
      Value: 43 kW
    6. Create: Max. thermal load #3473990
      Value: 47.20 kW
    7. Create: The combustion chamber #3473991
      Value: Open
    8. Create: Efficiency #3473992
      Value: 91 %
    9. Create: Control #3473993
      Value: Electronic
    10. Create: Installation #3473994
      Value: Floor
    11. Create: Primary heat exchanger material #3473995
      Value: Cast iron
    12. Create: Mains voltage #3473996
      Value: Single-phase
    13. Create: Peculiarities #3473997
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: The volume of the built-in boiler #3473998
      Value: 130 l
    15. Create: Expansion tank volume #3473999
      Value: 12 l
    16. Create: Equipment #3474000
      Value: Built-in boiler, display
    17. Create: Fuel #3474001
      Value: Diesel fuel
    18. Create: Fuel consumption #3474002
      Value: 3.98 kg/h
    19. Create: Heat carrier temperature #3474003
      Value: 50 - 82 °С
    20. Create: Temperature in the DHW circuit #3474004
      Value: 35 - 57 °С
    21. Create: Hot water capacity at t 30°C #3474005
      Value: 26.5 l/min
    22. Create: Max. water pressure in the DHW circuit #3474006
      Value: 7 bar
    23. Create: Max. water pressure in the heating circuit #3474007
      Value: 3 bar
    24. Create: Heating circuit connection #3474008
      Value: 1"
    25. Create: Branch pipe for connecting the DHW circuit #3474009
      Value: 3/4"
    26. Create: Chimney diameter #3474010
      Value: 150 mm
    27. Create: Dimensions WxHxD #3474011
      Value: 600x1600x800mm
    28. Create: Weight #3474012
      Value: 310.8 kg
    29. Create: Additional Information #3474013
      Value: DHW expansion tank: 5 liters; DHW circulation pump; safety valve of the DHW circuit; filter for diesel fuel; the presence of a low-temperature and high-temperature zone
    30. Create: Image #6335898
      URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id2484869330347395522.jpeg/orig
    31. Create: Preview image #6335899
      URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id2484869330347395522.jpeg/orig
  2. Donny Darko 30 April 2023 08:42:16
    Name: Liquid fuel Nova Florida LYRA BTF 43 V 43 kW double-circuit; Catalog: Heating boilers