Change history for item: Liquid fuel Nova Florida LYRA BTF 43 43 kW double-circuit

  1. Donny Darko 08 July 2023 12:35:39
    1. Create: Description #3473956
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3473957
      Value: Liquid fuel, classic
    3. Create: Burner #3473958
      Value: Liquid fuel
    4. Create: Number of circuits #3473959
      Value: Double-circuit
    5. Create: Max. thermal power #3473960
      Value: 43 kW
    6. Create: Max. thermal load #3473961
      Value: 47.20 kW
    7. Create: The combustion chamber #3473962
      Value: Open
    8. Create: Efficiency #3473963
      Value: 91 %
    9. Create: Control #3473964
      Value: Electronic
    10. Create: Installation #3473965
      Value: Floor
    11. Create: Primary heat exchanger material #3473966
      Value: Cast iron
    12. Create: Mains voltage #3473967
      Value: Single-phase
    13. Create: Peculiarities #3473968
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: The volume of the built-in boiler #3473969
      Value: 130 l
    15. Create: Expansion tank volume #3473970
      Value: 12 l
    16. Create: Equipment #3473971
      Value: Built-in boiler
    17. Create: Fuel #3473972
      Value: Diesel fuel
    18. Create: Fuel consumption #3473973
      Value: 3.98 kg/h
    19. Create: Heat carrier temperature #3473974
      Value: 50 - 82 °С
    20. Create: Temperature in the DHW circuit #3473975
      Value: 35 - 57 °С
    21. Create: Hot water capacity at t 30°C #3473976
      Value: 26.5 l/min
    22. Create: Max. water pressure in the DHW circuit #3473977
      Value: 7 bar
    23. Create: Max. water pressure in the heating circuit #3473978
      Value: 3 bar
    24. Create: Heating circuit connection #3473979
      Value: 1"
    25. Create: Branch pipe for connecting the DHW circuit #3473980
      Value: 3/4"
    26. Create: Chimney diameter #3473981
      Value: 150 mm
    27. Create: Dimensions WxHxD #3473982
      Value: 600x1600x800mm
    28. Create: Weight #3473983
      Value: 296 kg
    29. Create: Additional Information #3473984
      Value: DHW expansion tank: 5 liters; DHW circulation pump; safety valve of the DHW circuit; diesel fuel filter
    30. Create: Image #6335896
      URL: https://avatars.mds.yandex.net/get-mpic/4489193/img_id2886746998059434916.jpeg/orig
    31. Create: Preview image #6335897
      URL: https://avatars.mds.yandex.net/get-mpic/4489193/img_id2886746998059434916.jpeg/orig
  2. Donny Darko 30 April 2023 08:42:16
    Name: Liquid fuel Nova Florida LYRA BTF 43 43 kW double-circuit; Catalog: Heating boilers