Change history for item: Gas Nova Florida DELFIS CONDENSING KC 12 11.7 kW double-circuit

  1. Donny Darko 08 July 2023 12:31:43
    1. Create: Description #3473360
      Value: Type of heating boiler: gas, max. heat output: 11.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3473361
      Value: Gas, condensing
    3. Create: Burner #3473362
      Value: Gas
    4. Create: Number of circuits #3473363
      Value: Double-circuit
    5. Create: Thermal power #3473364
      Value: 1.80 - 11.70 kW
    6. Create: Thermal load #3473365
      Value: 2 - 12 kW
    7. Create: The combustion chamber #3473366
      Value: Closed
    8. Create: Efficiency #3473367
      Value: 105.1 %
    9. Create: Control #3473368
      Value: Electronic
    10. Create: Installation #3473369
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3473370
      Value: Stainless steel
    12. Create: Mains voltage #3473371
      Value: Single-phase
    13. Create: Peculiarities #3473372
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3473373
      Value: 9 l
    15. Create: Equipment #3473374
      Value: Display
    16. Create: Fuel #3473375
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3473376
      Value: 1.27 cu. m/hour
    18. Create: LPG consumption #3473377
      Value: 0.93 kg/h
    19. Create: Nominal pressure of natural gas #3473378
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3473379
      Value: 37 mbar
    21. Create: Heat carrier temperature #3473380
      Value: 20 - 83 °C
    22. Create: Temperature in the DHW circuit #3473381
      Value: 35 - 62 °С
    23. Create: Hot water capacity at t 25°C #3473382
      Value: 10.3 l/min
    24. Create: Hot water capacity at t 30°C #3473383
      Value: 8.6 l/min
    25. Create: Max. water pressure in the DHW circuit #3473384
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3473385
      Value: 3 bar
    27. Create: Gas connection #3473386
      Value: 1/2"
    28. Create: Heating circuit connection #3473387
      Value: 3/4"
    29. Create: Connection of a separate chimney diameter 80 mm #3473388
      Value: Yes
    30. Create: Dimensions WxHxD #3473389
      Value: 400x700x250mm
    31. Create: Weight #3473390
      Value: 28.4 kg
    32. Create: Image #6335840
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id5754230947412897401/orig
    33. Create: Preview image #6335841
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id5754230947412897401/orig
  2. Donny Darko 30 April 2023 08:42:08
    Name: Gas Nova Florida DELFIS CONDENSING KC 12 11.7 kW double-circuit; Catalog: Heating boilers